Critical Power: Circuit protection in health care facilities

Engineers must understand and apply circuit protection best practices especially when designing electrical systems in health care facilities.

08/08/2013

Flash is required!

Health care facilities and hospitals have more stringent circuit protection requirements than conventional building electrical systems. Because of the unique constraints of health care facility electrical systems, design engineers must ensure these demanding requirements are met. However, codes adopted in many jurisdictions don't provide a significant amount of guidance regarding feeder and branch circuit design for health care facilities. Engineers must understand and apply circuit protection best practices especially when designing electrical systems in health care facilities.

Learning objectives:

  • The audience will understand the applicable codes: NFPA 70: National Electrical Code, Article 517, NFPA 99: Health Care Facilities Code, and NFPA 110: Standard for Emergency and Standby Power Systems
  • Attendees will understand the coordination, overcurrent, short-circuit, and ground-fault protection issues for health care facilities.
  • Viewers will learn about feeder protection design requirements for health care facilities.
  • Viewers will learn about branch protection design requirements for health care facilities.

Speakers:

Neal Boothe, PE, exp US Services Inc., Maitland, Fla.

James Ferris, PE, TLC Engineering for Architecture, Orlando, Fla.

Moderator: Amara Rozgus, Editor in Chief/Content Manager, Consulting-Specifying Engineer, Pure Power, and CFE Media LLC



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me