Creating Value in Engineering Firms

Professional engineering firms traditionally have had difficulties in transitioning their firms. When the originating generation wishes to retire, three options frequently taken are:If the plan is to sell, the eventual price is largely determined by the final buyer's perceived value.

03/01/2001


Professional engineering firms traditionally have had difficulties in transitioning their firms. When the originating generation wishes to retire, three options frequently taken are:

  • Sell or merge with an outside firm.

 

  • Sell to internal employees.

 

  • Close the doors.

If the plan is to sell, the eventual price is largely determined by the final buyer's perceived value. Careful planning and time can substantially increase returns, and allow the seller to maximize the several variables that influence the price.

There are multiple methods of valuing firms, including use of multiples of book value, price-to-earnings (P/E) ratios, discounted cash flow and multiples of earnings before interest, taxes, depreciation and amortization (EBITDA).

Currently, the EBITDA method is favored; its value is another way of describing pretax cash flow, and design firms typically sell for a multiple of 1.5 to 3.0 times EBITDA plus a percentage of assets. In addition to the EBITDA, principals' compensation (i.e., distributions) in excess of a normal compensation package should be added to cash flow. By projecting current or average of recent years EBITDA, it is possible to estimate a future firm sale price.

The first step in planning a future transaction is to take stock of the company. Among the data to measure are:

  • Sales trends.

 

  • Profitability.

 

  • EBITDA.

 

  • Utilization ratios.

 

  • Strengths and weakness of key people.

Once these factors are assessed, multiple scenarios can be projected, including increased profitability, expanded revenues, expansion by acquisition or hiring key people.

A case study

For example, Alpha Engineering had a gross income of $3,650,000 last year. There are two principals, both in their fifties. The firm's EBITDA was $650,000, or 17.8 percent. The firm's income over the last several years has been steady, but not increasing. Alpha has now won several long-term contracts and feels confident that income will dramatically increase. In addition to what the firm already knows, the principals hope to expand even more and set a goal of increasing fees to $10 million by 2007. If Alpha reaches these goals, the EBITDA will be $1,780,000 in the final year. To obtain this, Alpha will have to market more aggressively or acquire another firm, or both. The costs associated with such acquisitions or marketing campaign would put downward pressure on the EBITDA.

Alpha reviews their plan and feels the $10 million figure is not obtainable. They decide to set the 2007 goal for $7 million. Alpha also knows their profit margin of 15.3 percent of fees or 17.8 percent EBITDA is low and decides to increase profit to 20 percent of fees-or 22.6 percent EBITDA-if they can implement better cost controls. When Alpha projects $10 million in fees, the EBITDA is $1,780,000. However, with the reduced goal of $7 million and a 20-percent profit, the EBITDA is $1,582,000, or $198,000 less. Therefore, Alpha concluded that the risks associated with trying to gain an additional $3 million in fees would produce an additional 6.6 percent in EBITDA.

In addition to increasing the company's income and net profit, the principals are preparing for their retirement. They have decided that now is the time to start making plans. Furthermore, they are aware that there are several options: selling to a third party, an employee stock-ownership plan or an internal sale.

New firm owners

The next step for Alpha's principals is to identify key employees who should become owners in the firm. In the process, they identify two possible leaders. However, they also decide that these leaders do not have the business acumen necessary to carry the firm forward. Therefore, part of the transition plan must include recruiting a potential future owner with greater business skills. The next step for Alpha's principals is to form a management leadership team with these key employees. In an upcoming meeting, the key employees will be told that the firm is making plans for a transition and that the principals wanted to include them.

A third member of the leadership team is hired and the two principals take a year to review each team member's performance. The two original principals give each of the team members a 10-percent interest in the firm. There are buy/sell agreements executed, allowing the firm to repurchase the stock at a minimal rate should any of the team leave. To receive the stock, the junior members are required to pledge-for the duration of the transition period-the funds in an account that will eventually be used to buy out the senior principals. The new members are also required to agree that each member of the team will receive salaries and bonuses. Salaries and bonuses will continue being paid roughly as they have been previously, and only the senior principals will receive their salaries, bonuses and dividends, because they will not contribute to the fund.

Compensation for the two senior principals for the year 2000 totaled $500,000, and they agreed that their salaries and bonuses would remain the same until 2007. Income beyond their compensation would be used for dividends, of which 70 percent would be retained by the senior principals and thirty percent would be invested in the junior principal's fund. According to the Table on page 15, should the plan meet its projections, that fund will grow to over $2.5 million in 2007, and be available to partially fund the junior partners' purchases of the senior partners' stock.

If the firm is valued at three times EBITDA or $4,746,000, the senior principals' 70 percent of the firm would be valued at $3,322,200. The remaining $817,547 plus 70 percent of the hard assets at market value are still owned by the senior principals and can be financed.

Options open

Business results for the next seven years are likely to vary from today's projections. The principals' plans are also very likely to change over the course of seven years. However, what the above case demonstrates is that because senior principals have planned their retirement, they have options. They no longer need to sell to the first party with cash; but should the firm receive an attractive outside offer, that too can be considered.

Also, because the firm now has junior partners-and because personnel are an engineering firm's main assets-the firm will appear more attractive to external purchasers. The buyer can discuss face-to-face with the junior principals their futures. Those meetings are also likely to aid in transition with the balance of the staff, should an outside sale occur.

The above case study is only an example and does not consider the legal and tax consequences. The senior principals' attorneys and accountants should be consulted to maximize the return on a transition.

Alpha Engineering - A Case Study


20002001200220032004200520062007


Income


3,650


4,129


4,607


5,086


5,564


6,043


6,521


7,000


Profit 15.3%


558


632


705


778


851


925


998


1,071


EBITDA 17.8%


650


735


820


905


990


1,076


1,161


1,246


Goodwill at 1.5 EBITDA


975


1,102


1,230


1,358


1,486


1,613


1,741


1,869


Goodwill at 3 EBITDA


1,949


2,205


2,460


2,716


2,971


3,227


3,482


3,738


Income


3,650


4,129


4,607


5,086


5,564


6,043


6,521


7,000


Profit 20%


826


921


1,017


1,113


1,209


1,304


1,400


EDIBTDA 22.6%


933


1,041


1,149


1,258


1,366


1,474


1,582


Goodwilll at 1.5 EBITDA


1,400


1,562


1,724


1,886


2,049


2,211


2,373


Goodwill at 3 EBITDA


2,799


3,124


3,448


3,773


4,100


4,422


4,746


Dividends from EBITDA


85.2


170


255


341


426


511


596


Sr. partners 70% of dividends


59.6


119


179


239


298


358


417


Jr. partner 30% dividends


25.6


51.1


76.6


102


128


153


179


Jr. partners fund additions


25.6


76.7


180


283


410


564


742


Savings interest 6%


2


6


17


35


62


100


Total in fund


25.6


104


290


590


1,036


1,662


2,505


Note: all figures in 1,000's





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me