Control valves for pressurized water reactors

Emerson Process Management received an $8 million contract to supply Fisher control valves for SCANA's nuclear generating stations in South Carolina.

08/19/2011


Westinghouse Electric Company has awarded Emerson Process Management more than $8 million in purchase orders for critical control valves to be used in two AP1000 pressurized water reactors at SCANA Corporation’s Virgil C. Summer Nuclear Generating Station in Jenkinsville, South Carolina. With site preparation already underway, construction is scheduled to begin late this year or early next year. The two new reactors are scheduled to begin commercial operation in 2016 and 2019, respectively.

Emerson was selected for this project based on its experience in producing valves for the same applications in other AP1000 plants. The Fisher control valves covered by the purchase orders are identical to those selected for the first four AP1000 nuclear power units being built in China and two additional units in the US Southeast.

Fisher air-operated control valves will serve as part of the safety-related system in the nuclear containment area. Engineered to comply with ASME Section III standards for components of nuclear facilities, they undergo rigorous qualification testing at the new Emerson Innovation Center in Marshalltown, Iowa. Valve actuators are sized in accordance with EPRI (Electric Power Research Institute) guidelines to ensure adequate operating margins that meet industry standards. They are also designed and tested to survive vibration loads of six times gravity in three axes to confirm they can operate after a seismic event.

For the passive residual heat removal system, Emerson developed a specially modified ball valve that meets all specified flow requirements and fits in the limited space available. These valves have received extensive testing to prove their ability to provide highly efficient flow through natural convection without assistance from the reactor coolant pump. Testing has also demonstrated tight valve shut-off when the plant is in operation to maintain efficiency and accurate throttling control for all flowing conditions.

www.emersonprocess.com 

Emerson Process Management



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me