Condensing boilers

Condensing boilers to include three models with 750,000, 1.0 million, and 1.25 million Btu/hr inputs.

04/02/2015


Condensing Boilers to include three models with 750,000, 1.0 million and 1.25 million Btu/hr inputs.CREST Boilers are designed with a top-mounted micro-metal fiber burner, engineered specifically for fire-tube technology. The Wave fire-tube configuration creates turbulence as flue gas products flow down the tube, scrubbing the energy. As water flows up the vessel, super-heated flue products flow down the fire tubes. With one pass, heat is transferred and flue gases reach condensing temperatures. With an 8-in. touchscreen and multi-color interface, the SMART TOUCH operating system provides control and easy-to-use monitoring functions. The SMART TOUCH control can be integrated directly into a building automation system through BACnet, ModBus, and other communication protocols using a gateway device. Cascade sequencing can be programmed for lead-lag or efficiency optimized operation. Fire-tube technology also allows CREST boilers to operate over a wide range of flow rates with very low pressure drop, allowing for a full flow system. 

Lochinvar LLC

www.lochinvar.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me