Compact multicore controller uses Intel Core i7 processor

National Instruments cRIO-908x system is NI's first multicore CompactRIO with an Intel Core i7 Processor. Also announced at NIWeek are the smallest NI single-board RIO Devices. These products expand the NI RIO advanced control and monitoring platform with higher-performance and smaller form factor targets.

08/02/2011


National Instruments today announced at its NIWeek conference, the expansion of the NI reconfigurable I/O (RIO) platform with the addition of the highest performance and first multicore NI CompactRIO systems and smallest NI Single-Board RIO devices.

National Instruments cRIO-908x system is NI's first multicore CompactRIO with an Intel Core i7 Processor. Also announced at NIWeek are the smallest NI single-board RIO Devices. Courtesy: NI

The new NI cRIO-908x systems, announced Aug. 2, feature an Intel Core i7 dual-core processor for increased processing power, Xilinx Spartan-6 field-programmable gate arrays (FPGAs) and the option of a Microsoft Windows Embedded Standard 7 (WES7) OS configuration for monitoring and control applications that require exceptional performance and the ruggedness of CompactRIO. For high-volume and OEM applications, the new NI sbRIO-9605/06 devices are sized from less than 102.87 mm x 96.52 mm and offer greater customization and I/O support than previous versions, the company said.

With the Intel Core i7 dual-core 1.33 GHz processor and up to a Xilinx Spartan-6 LX150 FPGA, the cRIO-908x systems deliver the highest processing power of any CompactRIO product and are ideal for performing complex signal processing and control within applications such as rapid control prototyping, advanced motion control and machine vision. The controllers can be configured with a WES7 OS, which gives engineers access to a broad ecosystem of Windows-based software and integrated graphics, or a real-time OS for reliable, deterministic performance. The systems provide a variety of high-performance peripheral connectivity including two Gigabit Ethernet ports, a MXI Express port, four USB ports, RS-232 and RS-485 serial ports and a new CPU eXpansion Module (CXM) that makes it possible to add custom connectivity and expansion to CompactRIO using industry standard protocols.

“By combining the power of the Intel Core i7 processor and the productivity of National Instruments integrated CompactRIO hardware and LabVIEW software, we are giving engineers a high-performance solution to quickly solve their advanced control and monitoring problems,” said Michelle Tinsley, general manager of the Intel Embedded Computing Division.

The new NI Single-Board RIO devices provide a small and cost-optimized form factor for the NI RIO platform and are ideal for embedded monitoring and control applications in industries such as energy and medical. The devices feature a 400 MHz processor and Xilinx Spartan-6 FPGA to provide reliability and performance at a low price point for OEMs. The devices also offer built-in peripherals such as RS-232, CAN, USB and Ethernet. Additionally, the new devices feature a high-density and high-bandwidth connecter that gives engineers direct access to the FPGA and processor as well as the ability to add peripherals for further customization.

"NREL is working directly with National Instruments to develop advanced power electronics inverter control hardware based on reconfigurable FPGA technology for renewable, electric vehicle and smart grid systems," said Dr. Bill Kramer, who manages research and development for Energy Systems Integration Technologies at The National Renewable Energy Laboratory. "With the new high bandwidth connector on these NI Single-Board RIO devices and LabVIEW programming tools, we now can take our simulations and advanced algorithms from prototype to high-volume, deployable targets more quickly than ever."

An integral part of the NI graphical system design approach, NI RIO technology combines NI LabVIEW system design software with commercial off-the-shelf hardware to simplify development and shorten time to market when designing advanced control, monitoring and test systems, the company said. NI RIO hardware, which includes CompactRIO, NI Single-Board RIO, R Series boards and PXI-based NI FlexRIO, features an architecture with powerful floating-point processors, reconfigurable FPGAs and modular I/O. All NI RIO hardware components are programmed with LabVIEW to give engineers the ability to rapidly create custom timing, signal processing and control for I/O without requiring expertise in low-level hardware description languages or board-level design, NI noted.

National Instruments said it is transforming the way engineers and scientists design, prototype and deploy systems for measurement, automation and embedded applications. NI empowers customers with off-the-shelf software such as NI LabVIEW and modular cost-effective hardware, and sells to a broad base of more than 30,000 companies worldwide, with its largest customer representing approximately 4 percent of revenue in 2010 and no one industry representing more than 15 percent of revenue. Headquartered in Austin, Texas, NI has approximately 5,500 employees and direct operations in more than 40 countries.
www.ni.com/compactrio 

www.ni.com/singleboard

www.ni.com

www.niweek.com

- Edited by Mark T. Hoske, CFE Media, Control Engineering, www.controleng.com.

http://www.controleng.com/new-products/plcs-and-pacs.html



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.