Compact, enclosed power supplies meet Eco-design Directive for Energy-Related Products

Carlo Gavazzi announces compact, energy saving SPP1 Series Enclosed Power Supplies meeting the Eco-design Directive for Energy-Related Products (ErP).

BY: Carlo Gavazzi Inc.

06/16/2011


Gavazzi enclosed power supplyCarlo Gavazzi SPP1 Series Enclosed Power Supplies are compact and complement the company's existing offering of SPD Industrial DIN-rail and SPM Low Profile Power Supplies. Despite their compact size, they are packed with features, such as high efficiencies up to 87% resulting in more energy to the dc load. Furthermore, with an mean time between failure (MTBF) of over 700,000 hours, users can be rest assured of a long and reliable service life.  The SPP1 Series requires little power in stand-by mode, as it consumes 0.3 watts. It is designed to meet the ErP standard (Eco-design Directive for Energy-Related Products). Short circuit HICCUP mode ensures the SPP1 Series can withstand a continuous short across the output, yet will automatically restart when the fault clears.              

Output voltages available are in 5, 12, 15 and 24 V dc, and are rated at 20, 35 and 60 W. The ac/dc universal input offers a full range of 88-264 V ac and 120-375 V dc making these ideal for OEMs requiring complete design flexibility, independent of available power sources. Carlo Gavazzi’s new SPP1 Series are  cRUus and TUV approved, CE marked and are RoHS compliant. Features include:

  • Universal inputs 88-264 V ac and 120-375 V dc
  • 5, 12, 15 and 24 V dc outputs
  • Output power rated at 20, 35 and 60 watts
  • Short Circuit Protected – HICCUP Mode
  • Internal input filter
  • High efficiency up to 87%
  • Overload protection to 160%
  • MTBF in excess of 700,000 hours
  • Low stand-by power consumption: 0.3 W
  • cRUus, TUV, CE and RoHS

The power supplies are available from Carlo Gavazzi’s North American network of sales offices, distributors or www.GavazziOnline.com

- Edited by Kelsey Kirkley, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.