Compact embedded PC can serve as PLC, motion controller

The CX9020 Embedded PC by Beckhoff Automation features a 1 GHz ARM Cortex A8 processor and can become a PLC and motion controller with automation software.

05/29/2013


The CX9020 Embedded PC by Beckhoff Automation features a 1 GHz ARM Cortex A8 processor and can become a PLC and motion controller with automation software. Courtesy: Beckhoff AutomationThe CX9020 Embedded PC by Beckhoff Automation is DIN rail mounted and equipped with a powerful 1 GHz ARM Cortex A8 processor. The CX9020 is suitable for a wide range of PLC and motion control applications in small and medium sized machines, systems or buildings.

The CX9020 integrates a CPU, numerous connectivity solutions and optional interfaces, a power supply and a direct I/O interface for Beckhoff I/O systems, all in one compact housing. The CX9020 can operate in demanding environments with temperatures ranging between -25 to +60 °C making it ideal for a wide range of manufacturing facility types and outdoor applications, including wind turbines and solar power installations.

In combination with the TwinCAT automation software platform from Beckhoff, the CX9020 becomes a dependable PLC and motion controller that can be used with or without visualization.

The solid-state CX9020 is fanless and equipped with two microSD card slots providing the option for larger storage capacity on the device. It also comes with a 256 MB microSD card for the operating system; the supplemental microSD card slot can be used for additional operator data. The CPU inside the CX9020 has access to an impressive 1 GB of internal DDR3 RAM memory. In addition, 128 Kbyte of NOVRAM are available for data storage in the event of a power failure.

The basic configuration of the CX9020 includes two switched Ethernet 10/100 Mbit/s RJ 45 interfaces, four USB-2.0 interfaces and a DVI-D interface. The RJ 45 interfaces are connected to an internal switch and offer a simple option for creating a line topology without the need for additional Ethernet switches. A “multi-optional” interface permits the integration of an additional interface, such as EtherCAT (slave only), Profinet, EtherNet/IP, Profibus, CANopen, DeviceNet, serial interface (RS232/RS422/RS485) or audio.

Another smart feature of the CX9020 is its ability to automatically detect the directly-connected Bus Terminal I/O or EtherCAT Terminal I/O and switch to the respective mode for convenient system management.

Beckhoff Automation

www.beckhoff.com 

See other Control Engineering controller products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me