Compact AC drive for open- and closed-loop applications

Allen-Bradley PowerFlex525 AC drive by Rockwell Automation is designed for a number of applications including material handling and compressors. It also has several motor control options for open- and closed-loop applications.

03/19/2013


The PowerFlex525 AC drive by Rockwell Automation is designed for a number of applications including material handling and compressors. It also has several motor control options for open- and closed-loop applications. Courtesy: Rockwell AutomationRockwell Automation's Allen-Bradley PowerFlex 525 AC drive to help machine builders and end users simplify equipment design and operation, and speed installation and configuration. The PowerFlex525 AC drive features a modular design in power ranges from 0.5 to 30 horsepower or 0.4 to 22 kilowatt at 100 to 600 volt input. Its embedded EtherNet/IP, safety, USB programming, energy savings and a variety of motor control options are designed for machine-level and stand-alone applications or simple system integration.

Suitable for a wide range of applications, including conveyors, material handling, compressors, fans and pumps, the PowerFlex 525 AC drive provides a variety of motor control options to accommodate open- and closed-loop applications.

The PowerFlex 525 AC drive offers application sets, which are groups of pre-defined parameters for common drive applications that users can apply “as is” or customize for a machine. Using a standard USB connection, machine builders can easily download the completed configurations and share with multiple drives, which speeds up commissioning time.

Removing the control module from the power module further reduces startup time because configuration and installation can be done simultaneously. MainsFree programming through a USB connection removes the need for main power during drive configuration, as well as the need for special adapters to communicate between the drive and the programming tools.

Embedded EtherNet/IP connectivity optimizes integration with programmable controllers to deliver more application flexibility. Optional dual-port EtherNet/IP connectivity supports device level ring (DLR) topology, providing a robust network infrastructure.

An SIL2/PLd-certified, embedded safe torque-off feature helps prevent drive restarts after a safety circuit is tripped, ultimately helping to protect personnel and equipment, and minimize production losses. The drive’s economizer mode helps optimize motor energy consumption by monitoring an application’s current demand and automatically refining operating parameters accordingly.

The PowerFlex 525 AC drive requires 50 mm (2 inches) of clearance on the top and bottom when installing into a cabinet and can be mounted zero-stacked both horizontally and vertically. This smaller clearance can help customers reduce the panel space required for their application.

Rockwell Automation

www.rockwellautomation.com 

- Edited by Control Engineering. See other motors and drives products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me