Commissioning and the technology evolution

With smarter application and availability of technology to achieve and drive longer-term performance results, commissioning providers (CxPs) are finding themselves at the forefront to learn, coach, and lead the application of technology in the built environment. Learn the challenges, roles, opportunities, and recommended methods for incorporating technology solutions into the commissioning process and improving building performance.

03/17/2016


Figure 1: This shows the commissioning authority conducting point-to-point testing of building systems. Courtesy: McKinstryLearning objectives:

  • Demonstrate how technology is affecting the commissioning marketplace.
  • Show how commissioning providers (CxPs) can leverage technology to increase business and offer their customers a more comprehensive building performance solution.
  • Apply commissioning (Cx) best practices to technology-driven commissioning applications.
  • Navigate technology challenges and opportunities in the built environment through the commissioning process.

Building technology solutions are accelerating at an exponential pace, rapidly changing the building industry. The challenges at this nexus are to keep up with innovations and be able to marry technology solution capabilities with appropriate and successful implementation for building owners and managers. Commissioning providers (CxPs) are jumping into this technical evolution to ensure building owners' project requirements are fulfilled.

The impact of technology on the commissioning profession is dramatic. Technology applications provide platforms for multilevel data gathering, analytics, performance assessment, and problem identification, and allow project teams to reach consensus faster. Although there is not yet a single "all-in-one" commissioning technology solution, a host of available technology applications are available today that can acquire real-time building and systems performance data, test for various conditions, simulate seasonal performance, and provide monitoring-based commissioning (MBCx) over time.

Market challenges

This technology-based commissioning market is in its infancy. The building-focused "technology bubble" has created a multitude of technologies rushing into the market at a high rate of speed, adoption, and consequent confusion. Data, analytics, and business intelligence solutions are viable and available; yet, with myriad applications, they are not easily integrated together. Like the dot.com bubble, there are currently no gatekeepers or metrics for building technology solutions that deliver what owners intend, except through the process of commissioning. Challenges include:

  • Best practice gaps. Professionals with diverse backgrounds—from engineering consultants to systems integrators and architects—are jumping on the bandwagon without the necessary knowledge, skills, or experience to understand the best practices for technology applications, or the best use of data they acquire. There are more players than ever in the marketplace, and CxPs need to stay on the leading edge to learn continuously about technology offerings that allow them to supplement the commissioning process.
  • App choices and data deluge. Building owners and managers have picked up on the buzz. They are hearing about the efficiency and savings potential as well as the speed and ease of data analytics that they can achieve if they purchase the latest shiny new "big data" applications. As a result, they are savvy but confused by the deluge; they read blogs, run their days, and coordinate tasks through handheld apps. They understand that information can lead to efficiency, but more data is only better if they know what they need to do with it. Without guidance from leaders of technological building applications, the big data market will continue to evolve undirected, creating further market fragmentation and additional confusion for the buyers of commissioning services.
  • From the building owners' perspective, the array of technology choices, analytical methods, and outcomes can be daunting. The knowledge necessary to make the right choice, for the right reasons, is time-consuming and does not always produce the desired result.
  • Performance goals. Building project owners, planners, designers, and other stakeholders need to understand the building-performance improvement goals before shopping for a big data analytics solution. They need to vet big data applications to determine if their needs are met by the features and functions of the solution. They also need assistance in understanding how much data is enough and how much is overload that bogs down both system and operations performance. A complete picture of building performance is only available when one has and analyzes all building data, automation system data, energy data, equipment data, service work orders, etc. Each set of data provides valuable information. Big data analytics firms may position their work as comprehensive, but if they are examining just one set of data, it is only a partial picture of building systems operation at best.
  • Limited holistic solutions. Not many experts provide holistic solutions. Fragmented information sources such as trade shows, presentations, blogs, technical websites, and other resources make it hard to differentiate ecosystem solutions. Most provide individual value by the piece; at this juncture there are a lot of startups and intercompany consolidations, rendering many software solutions unsupported. For example, Cisco jumped into this market for a short time 5 years ago, deploying its building management tool, Mediator, which intended to "tap into Cisco's deep networking skills to hook up the many and disparate software networks used to heat, cool, and otherwise operate big commercial buildings." After trying to improve and expand, it discontinued the entire line of building energy-management products, leaving customers without recourse for servicing their investment.

Where does all of this leave the commissioning profession, which is focused on boots-on-the-ground building science and high performance underpinned by a construction-industry mentality? CxPs have been slow to accept "unproven" technology tools, waiting and evaluating the outcomes they see, knowing there may be financial and resource risk implications if they get it wrong.

Figure 2: Commissioning field verification is conducted on a data center’s air-cooled chilled water system. Courtesy: McKinstryThe role of CxPs in technology-centric buildings

Despite some pessimistic opinions, technology is not causing commissioning to go away. In fact, technology as a commissioning tool enables providers to assess more data points and deliver more depth, efficiency, and value to owners. As technology advances in buildings and as the line between information technology (IT) and facility-centric systems blurs, commissioning is becoming even more critical to ensure whole-building performance across integrated, advanced systems applications. More—and more effective—use of data also means less sampling of building systems, more accuracy, and lower cost of projectwide performance measurement.

Technology tools speed up access to useful data. Well-conceived and integrated technology assists CxPs to test data quality and commission the analytics, run trends, identify fixes, analyze issues, and conduct point-to-point functional-performance testing at scale. CxPs can use technology to cast a wider net by monitoring control points and subsystem energy use and by relating results to the utility meter. Technology helps CxPs evaluate performance back to design, closing the long-existing gap between design intent and ongoing operational performance.

The role of CxPs in a technology-centric building environment is changing, and new questions are springing up along the way:

  • Where does technology fit in the commissioning value proposition?
  • How can CxPs further leverage and apply technology solutions for the design, construction, and operation of buildings?
  • To what degree should CxPs compel IT/building software personnel and building industry professionals to come together as technology blurs the line between fields?
  • How do CxPs deliver commissioning services that address big changes in building approaches like security, resiliency, and technology advancements?
  • Data volume and quality—how much is enough?

The answers to these questions are evolving as CxPs expand their use of technology tools in the commissioning process.


<< First < Previous Page 1 Page 2 Next > Last >>

Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me