CMMS "on the go"

So often prospects and clients ask me how to “go mobile” with CMMS. Their question typically starts off in the middle of the mobile process: “I want to use barcode scanning. Where do I begin?”

Paul LaChance

02/13/2013



So often prospects and clients ask me how to “go mobile” with CMMS. Their question typically starts off in the middle of the mobile process: “I want to use barcode scanning. Where do I begin?” My response? “Dive in deeper and figure out what you want to achieve as you make rounds on the plant floor with your mobile device in tow.”

Numerous paperless tasks can be achieved through mobile technology. But first, a few myths must be dispelled about mobile CMMS.

First myth: Your handheld device with built-in barcode will cover all CMMS tasks. Not a chance. Imagine using an iPhone or a Motorola unit and your thumbs to enter detailed work order data about belt rollers and bearing replacements on a conveyor belt. While you can capture data on work order status, repair history, replacement parts, or lockout-tagout emergency procedures on the go, you will still need to enter additional details on your desktop. 

Second myth: Barcodes have practically replaced manual data entry. Again, wishful thinking. The primary function of barcode scanning mobile device is to link to detailed assets or parts information already in your CMMS (mobile or otherwise). Once you locate a particular asset you’ll have access to repair instructions, lockout-tagout procedures, check parts inventory, the ability to close work orders (WOs), etc. Barcodes are a big help, but they won’t dramatically change your maintenance processes. You’ll still have to perform some CMMS chores from your desktop even if you locate asset information on the go.

But there are benefits galore! For the technician, mobile CMMS replaces walking around with stacks of paper work orders. You can take meter readings, make/examine/update WOs, inventory spare parts, and look up critical asset information (shutdowns, LOTO, etc.)—all from the palm of your hand. Many mobile CMMS systems have real-time connections to the main CMMS database, so updates and research are the same as your desktop version. From your mobile dashboard you can check the status of a scheduled PM, issue a new WO (or request), review asset repair history, and more. However, reporting and analysis is best performed from your desktop rather than from a handheld, with the exception of basic dashboard information.

What type of hardware should you buy? That debate has been going on for many years. There are basically two ways to go mobile with CMMS. Although you can purchase inexpensive “consumer devices” readily available at big-box electronic stores, they may not survive the industrial environment and won’t have high-quality barcode scanning capabilities. But if budget constraints prevail, consumer devices are a fraction of the cost of true industrial strength units, which are far more durable and come with integrated, feature-rich barcode scanners. For heavier use in less-forgiving environments, invest in rugged industrial units.

Tablet-style devices are also an option. iPads, Droids, and ruggedized Windows-based tablets, which are more durable, are readily available. Windows-based devices work well since they most likely run your other business applications. Before you run out and buy 20 mobile units, check if your CMMS provider has a mobile, browser-based version and try it on your iPhone or smartphone first. As a maintenance manager or technician, figure out how you plan to use it first, then research appropriate hardware. While reducing paper is the ultimate goal, getting data in real time from the palm of your hand will improve operations.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.