Circuit breaker for wind applications

Eaton Corp.’s VCP-Wind medium-voltage vacuum circuit breaker is designed specifically for wind applications.

10/03/2011


Eaton Corp.’s VCP-Wind medium-voltage vacuum circuit breaker is designed specifically for wind applications. The compact circuit breaker is engineered to provide reliable and robust circuit protection for wind farm collector substations. The VCP-Wind circuit breaker incorporates Eaton’s vacuum interrupting technology. Eaton’s vacuum interrupters avoid the use of sulfur hexafluoride (SF6), which poses environmental and safety concerns. They are designed to switch high stress currents, and require no cooling or ventilation systems. Additionally, they are encapsulated in epoxy resin material and are designed to require virtually no maintenance over the product lifecycle. Eaton’s new 38 kV VCP-Wind breakers offer current ratings up to 2,000 A without fan cooling and 31.5 kA. They meet American National Standards Institute (ANSI) and Institute of Electrical and Electronics Engineers (IEEE) C37.09 standards.

www.eaton.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.