Centrifugal chiller with environmentally sustainable refrigerant

Carrier's AquEdge 19DV centrifugal chiller with Greenspeed intelligence and a low Global Warming Potential (GWP) refrigerant.

03/30/2017


Carrier's AquEdge 19DV centrifugal chiller with Greenspeed intelligence and a low Global Warming Potential (GWP) refrigerant.Carrier's AquEdge 19DV centrifugal chiller with Greenspeed intelligence and a low Global Warming Potential (GWP) refrigerant. Improvements in compression technology and integration of Carrier’s Greenspeed intelligence variable-speed technology enabled Carrier to improve its centrifugal full- and part-load efficiencies. The result is the high-efficiency AquaEdge 19DV centrifugal chiller that saves energy costs and reduces environmental impact. The advanced two-stage compressor was designed and optimized for refrigerant R-1233zd(E), which has a GWP of 1.34 and an A1 safety classification per ASHRAE standard 34. The compressor’s low-speed direct drive back-to-back design significantly improves efficiency while balancing internal forces, enabling the use of energy-saving ceramic bearings that utilize the refrigerant already in the chiller as lubricant. The intuitive touch screen user interface provides graphical trending and remote access capability and can be mounted on any corner of the machine. 

Carrier

www.carrier.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me