Building Information Models

06/01/2006


From our June 2006 Specifiers Guide

Today a new technology, known as Building Information Models (BIM), is emerging that promises to change completely how we design buildings.

This technology goes beyond computer-aided design (CAD). BIM offers the opportunity to digitally build a structure from the start. Using BIM, all participants in a project have the opportunity to share information in a virtual environment—from plans to specifications to schedules.

The building design is created as a 3-D model that is stored as data in an object-oriented database. Drawings in two and three dimensions are generated from the BIM database. As data changes or as work progresses, the virtual building model is modified. BIM can reduce errors because everyone involved in the project can have access to the same information.

BIM's exciting potential lies in 4-D, object- and process-oriented systems. Everyone on the team can have access to up-to-the minute schedules, reports, drawings and visualizations from design and construction to operation and maintenance.

With object-oriented BIM, a part of the building entered into the system is not merely a graphical representation, but behaves like an actual window or wall or door in relationship to other building components. When an object is changed, the other objects adjust in real time, reducing design contradictions. Architects and engineers can work on the design at the same time because they can have access to a central model.

With more accurate information, and building elements that interact with each other, BIM offers engineers and consultants a better way to validate design assumptions in a virtual environment. This method of virtual simulations is more efficient than conducting them in the field.

The Construction Specifications Institute is involved with BIM because for more than five decades the organization has been driven by its mission to organize and streamline storage and retrieval of information necessary for defining building projects. The need for efficient exchange of information contained in building models is why CSI is participating in standards initiatives like the National Institute of Building Sciences' (NIBS) process to develop a National BIM Standard. A national standard will ensure that systems and applications can be interoperable. When the information for a project can be easily understood and communicated to all the participants, it can make the building process more efficient and cost-effective.

It took about 20 years for the industry to fully adopt CAD systems. BIM likely will be adopted much faster because the potential benefits are so compelling.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me