Broadband signal analyzers

Scout, Hunter, and Explorer Signal Analyzers by Aeroflex cover a wide range of applications including communications signals for commercial, military and aerospace applications.

02/10/2012


Scout, Hunter, and Explorer Signal Analyzers by Aeroflex cover wide range of applications including communications signals for commercial, military and aerospace applications. Courtesy: AeroflexAeroflex Incorporated, a wholly owned subsidiary of Aeroflex Holding Corp. (NYSE:ARX), announced a family of three low-cost broadband signal analyzers. These analyzers locate, record, and analyze complex communications signals for commercial, military, and aerospace applications.

The signal analyzer product family consists of a portable signal analyzer, the Aeroflex Scout CS1104, and two rack-mountable signal analyzers, the Aeroflex Hunter CS1207 and the Aeroflex Explorer CS1247. Common applications for the products are radar; communications; broadband RF test; satellites; electronic warfare (EW)/electronic countermeasures (ECM); spectrum monitoring; propagation measurement; electromagnetic environments (EME) analysis; wireless; and chip test. All products have an intuitive user interface based on Aeroflex BSA software, which is familiar to current BSA users and easy to navigate for new users.

The Scout CS1104 is a portable signal analyzer designed for the user who wants to go out in the field and to find signals of interest. Whether the task is collecting RF signals on the move, or analyzing them in the lab, the Aeroflex Scout allows for flexibility. Scout’s RF coverage extends from 20 MHz to 3 GHz with 40 MHz instantaneous bandwidth, an 8 GB signal capture RAM, and a 1 TB removable data storage disk. Scout is targeted to provide data analysis and recording for portable applications.

The Hunter CS1207 and Explorer CS1247 are rack-mountable signal analyzers. Hunter is ideal for users who wish to search for a specific signal, hone in on a narrower frequency range around that signal of interest, and to analyze it. Hunter’s RF coverage extends from 10 MHz to 6 GHz with 70 MHz instantaneous bandwidth, a 32 GB signal capture RAM, and an 8 TB removable data storage disk. It is designed for applications that need greater RF bandwidth than Scout and adequate memory for longer signal recordings.

The Explorer CS1247 combines Hunter’s existing narrowband capability with additional wideband capability. The Explorer is designed for the user who needs to explore, record, and analyze across a wide frequency range. Explorer’s RF coverage extends from 10 MHz to 6 GHz with operator-selectable 70 MHz or 400 MHz instantaneous bandwidths, a 32 GB signal capture RAM, and an 8 TB removable data storage disk. Like Hunter, Explorer can zero in on a narrow spectrum range to look at a specific signal, record it, and analyze it. Explorer also adds a capability for wideband signals such as radar, communications, and EW.

Software and hardware options

The family of Aeroflex BSAs incorporates a longer contiguous record time and solves a wider array of difficult problems more quickly than competitive products. Aeroflex BSA software has been used to collect and analyze RF signals for many years. The software is continually updated to solve emerging problems and new signal standards, as well as modifications to current signals. Scout, Hunter, and Explorer all include three BSA software modules—BSA Basic, BSA Modulation Domain, and BSA Scanning Spectrum Analyzer. Many other BSA software module options are also available for Scout, Hunter, and Explorer.

Software and hardware modules included with Scout, Hunter, and Explorer:

  • BSA Basic software module—includes spectrum, spectrogram, and time software displays
  • BSA Modulation Domain software module—calculates and displays AM, FM, and PM waveforms and their statistics
  • BSA Scanning Spectrum Analyzer software module—emulates a traditional spectrum analyzer to view any range of spectrum instantaneously
  • GPS hardware module option—provides positioning and time stamp for the collected data. This option is standard on Scout and can be ordered as an option for Hunter and Explorer.

Aeroflex Inc.

www.aeroflex.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

More about industrial networks: controleng.com/networks



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.