Avtron sigma 2 load bank control system

Avtron Sigma 2 Load Bank Control System optimizes power testing workflow.

04/17/2015


Avtron Sigma 2 Load Bank Control System optimizes power testing workflow.Emerson Network Power reports its Avtron Sigma 2 Load Bank Control System optimizes power testing workflow, saving time and manpower, by daisy chaining up to 14 portable load banks to test, set up, and adjust gensets and uninterruptible power supply (UPS) systems. The Avtron Sigma Control System, with advanced microprocessor-based control and instrumentation, is developed for load bank applications. Every Sigma-controlled load bank has its own embedded control unit complete with high-accuracy voltage and current transformers, all located within the load bank. Networking any combination of resistive, inductive, and capacitive Avtron Sigma-controlled Load Banks provides the flexibility to achieve power testing capacities of more than 50 MW. Automatic load control provides up to 16 timed load steps, including manual override and cyclic testing. The Avtron Sigma 2 IHT permanently retains automatic test and system options. A technician also can manually control load by selecting such parameters as percent load, or kW, kVA, and power factor. For transient-response testing, voltage and frequency of the last load change are captured and displayed on a dynamic graph.

Emerson

www.emerson.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me