ASHRAE provides guidance on energy audits

ASHRAE's second edition of Procedures for Commercial Building Energy Audits provides advice for engineers, energy auditors, building owners, managers, and government entities.

12/06/2011


ASHRAE has released updated guidance on building energy audits. While energy audits are a commonly used component of the industry, there is great diversity in the services delivered to customers, and little industry standardization. The second edition of Procedures for Commercial Building Energy Audits promotes best practices, provides “how-to’s” and fills a void in available information for engineers, building owners, managers and government entities. The new publication includes time-saving tips for energy auditors, how to hire an auditor, what to ask for in a comprehensive audit report and how to build a successful energy efficiency retrofit team.

“As we work to reduce energy consumption in our commercial buildings, we want to ensure that recommendations are cost effective, technically feasible, maintain safety and comfort and result in significant energy savings” Jim Kelsey, a member of Technical Committee 7.6, Building Energy Performance, and who oversaw the writing of the updated publication, said. “This volume focuses on how to improve energy audit best practices. Providing the best audits that we can will help move the industry forward to net zero buildings.”

Additionally, the publication addresses how to build a successful team, analytical methods, successful approaches to site visits, incorporating on-site measurements, economic evaluation of measures and how to organize an energy audit report that promotes action on the part of building owners and managers. It includes many tips for conducting energy audits and reviewing results prepared by others. For example, the top things to check for in when reviewing an audit report include verifying that:

  • Proposed measures are feasible and appropriate for the building;
  • Proposed measures meet applicable building codes;
  • Data are internally consistent;
  • Savings estimate methods follow established principles and methods;
  • Estimates of potential energy savings are reasonable compared to quick estimates and historical energy use;
  • Proposed cost estimates are reasonable relative to field experience;
  • Interactions between EEMs are identified and addressed;recommendations and report meet the project scope, goals and client’s needs;
  • Any financial discussion includes current and viable mechanisms available per the tax structure, location, and motivations of the client.

Another benefit of the new publication is a greatly expanded section of forms and template analyses, including “live” Excel spreadsheets, checklists and equipment-specific forms suitable for field collection of detailed commercial building data.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.