ASHRAE 32P open for public comment

ASHRAE Guideline 32P aims to improve the performance of all buildings by providing guidance on optimizing operation and maintenance of buildings to achieve low costs without sacrificing safety or functionality.

06/06/2011


The proposed ASHRAE Guideline 32P, Sustainable, High Performance Operation and Maintenance, currently open for public comment until July 4, 2011, will reportedly help improve the performance of all buildings by providing guidance on optimizing operation and maintenance of buildings to achieve the lowest economic and environmental life cycle cost without sacrificing safety or functionality.

The guideline will apply to the ongoing operational practices for buildings and systems with respect to energy efficiency, occupant comfort, indoor air quality, health, and safety. These systems include the building envelope, HVACR, plumbing, complementary energy systems, and utilities and electrical systems.

The guideline contains recommendations for three levels of building oversight: senior managers, facility managers, and technicians. Checklists for tracking the appropriate steps are reportedly being taken to move toward high-performance operation and maintenance are included for each.

Among the items on the checklist for facility managers are:

  • Develop and implement protocols for good facility/system documentation.
  • Investigate, identify, and implement appropriate levels of building intelligence.
  • Identify and implement appropriate performance metrics.
  • Benchmark against other similar facilities.
  • Establish performance baselines and targets. Institute a system for regular reporting and evaluation.

It is said that the guideline will provide the next steps beyond compliance with ANSI/ASHRAE/ACCA Standard 180, Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems, and provide concepts, methods and details that meet the intent of the “minimum standards of care” under ANSI/ASHRAE/USGBC/IES Standard 189.1, Standard for the Design of High Performance Green Buildings.

- Edited by Amanda McLeman, Consulting-Specifying Engineer, www.csemag.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me