Applying flexibility, safety, and control

Learning how flexible and configurable I/O can be applied to more than safety systems could open many doors regarding how engineers approach automation and control projects.

06/12/2013


The cover story in this issue of AppliedAutomation is as much about I/O as it is about safety. While safety systems are fundamental to critical processes and operations, extrapolating the implications of how flexible and configurable I/O can be applied to more than safety systems could open many doors regarding how engineers approach automation and control projects.

This issue also includes a case study about a safety system upgrade at the SLAC National Accelerator Laboratory at Stanford University. Although the lab’s original 1940s-era relay-based system was functional, it had exceeded its useful life span. The lab upgraded its relay-based safety system with a new control and safety platform based on a safety PLC, which includes a safety controller and distributed safety I/O. The new system provides SLAC with preventive maintenance alerts and diagnostic capabilities that were not possible with the relay-based system.

The third article revisits temperature control. Tuning PID control loops can be challenging, and this article offers guidance on proper loop tuning. While most modern temperature controllers employ auto-tune features, units from different manufacturers may not behave the same way. Because control loops are in fact closed loops, tuning is inherently application dependent. The quest for ideal tuning assumes that the system is properly designed. Because the physical environment is part of the loop, the available Btus must be appropriate for the load. As the authors state, “The system is tuned well when it heats up and settles quickly at setpoint and when the temperature settles at a new setpoint without oscillating excessively.” The authors also point out that “quickly” and “excessively” are relative terms. 

See links for ways to manage process safety.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me