An enlightened look at photovoltaic cost

Given the double digit growth in the photovoltaic industry, PV conversion of sunlight is quickly making economic sense. There are two basic types of PV systems: grid-connected and remote-storage. Grid-connected systems are connected directly to the building power system to supplement the power delivered by the local utility.

09/01/2007


Given the double digit growth in the photovoltaic industry, PV conversion of sunlight is quickly making economic sense.

There are two basic types of PV systems: grid-connected and remote-storage. Grid-connected systems are connected directly to the building power system to supplement the power delivered by the local utility. Remote systems often are deployed in areas where the cost to extend utilities is prohibitive.

Three types of commercially viable modules are monocrystalline silicon, polycrystalline silicon and amorphous silicon. The relatively new amorphous-silicon thin-film technologies often are deployed as integrated roof, building skin or canopy systems, called building integrated photovoltaic systems (BIPVs). BIPVs offer the advantage of multiple use, as both solar shade and electrical generation.

One should consider relative solar angles and siting issues to site an array properly. In our hemisphere, the sun tracks along a southerly route due to the earth’s inclination to the sun. This makes it important to orient the array to the south. Ideally, a zero azimuth is the optimal orientation, but a 10-degree variation one way or the other won’t affect a cost-effective output of the system. Select a tilted angle close to the array’s latitude.

One can expect the present cost to be in the range of $5 to $8 per peak watt (Wp), including installation costs and any burdens, though I have seen estimates as low as $4 to $5 per Wp. The final cost of a 20-kilowatt peak (kWp) fixed-grid system should be about $160,000.

A good benchmark is the USGBC LEED credit available with a 5% system—one that supplies no less that 5% of a facility’s demands. Smaller systems are equally viable.

It is important to select a design team with an intimate knowledge of simulation and modeling techniques. A baseline calculation using an energy modeling tool will be required.

A typical system produces about 9 Wp to 10 Wp per sq. ft. and about 10 kWh to 12 kWh per sq. ft. per year, depending on the geographic siting of the array. These numbers are improving by significant margins based on improved modules, but they should hold for budget purposes over the next year or so.

Let’s look at a 100,000-sq.-ft. office building. Given 6 Wp per sq. ft. (use demand, not connected load) this value becomes 600 kWp:

600 kWp X 5% = 30 kWp

30 kWp X $8 per Wp = $240,000

These numbers are conservative, but should get budgeting in the ballpark. For a reality check, consider that if the office building is constructed for $90 per sq. ft., it would cost $9 million. The $240,000 represents about a 2.6% increase in construction cost. In San Antonio, Texas, for example, one can expect a payback in 10 to 15 years. Payback could be half that time in areas with higher energy rates. Utilities are offering help in capitalizing PV projects because it improves their adherent to renewable portfolio standards. Considering that a systems offer a 25 year or more useful life, it will be generating free electricity for half or more of its useful life.

Editor’s note: A longer, more detailed version of this article can be found in the Electrical Community at www.csemag.com .



Considerations in PV design

Building integrated photovoltaic systems (BIPVs) function as both solar shade and electrical generation

Federal, state and local jurisdictions offer tax rebates for PV use

Utilities are stepping up to the plate by offering help in capitalizing PV

USGBC LEED credit offers a benchmark for the percentage of power PV provides



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me