American Aerogel Expansion of Production Capacity

System overhaul: American Aerogel Expansion of Production Capacity; Optimation

Source: Optimation

08/09/2012


Optimation mechanics, pipefitters, and electricians installed and expanded service lines to increase production capacity.Project name: American Aerogel Expansion of Production Capacity

Location: Rochester, N.Y.

Firm name: Optimation

Project type, building type: System overhaul, manufacturing

Project duration: 1.7 years

Project completion date: Sept. 30, 2008

Engineering challenges

American Aerogel, a company developing and manufacturing proprietary Aerogel insulation products, had been growing rapidly and needed to expand its production capabilities. Because demand for its product was so high, American Aerogel’s 24/7 operation required new equipment with process improvements to increase production and improve efficiencies. Because American Aerogel’s products are made with a proprietary one-of-a-kind aerogel called Aerocore, maintaining confidentiality of the products’ chemical makeup and patented manufacturing processes was/is of the utmost importance. Optimation continues to honor this confidentiality.

Solutions

American Aerogel needed to expand production capabilities to meet a growing demand for its insulation product.American Aerogel brought Optimation in early on to assess the existing production equipment, processes, and available space to increase capability to remove and recover solvents from its products. Optimation developed drawings with the layout of the new and relocated production equipment and associated services. Optimation’s skilled trades team, comprised of millwrights, pipefitters, riggers, and electrical and instrumentation mechanics, completed installation of all production equipment and associated components. In addition to installing new equipment, mechanics made modifications to existing services to increase capacity. These services included electricity, steam, compressed air and nitrogen supplies, and condensate return and process vapor recovery. Optimation also assembled and installed all instrumentation/control cabinets, and led debug and startup of all installed systems. After this project was completed, production capacity increased significantly. The addition of instrumentation and improved access to the process information improved productivity and product quality. 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.