Aluminum desiccant wheel

Semco's Unitary Wheel Cassette (UWC) Series is a latent energy recovery aluminum desiccant wheel that is designed and packaged as an HVAC drop-in replacement for polymer desiccant wheels in most unitary ERV brands.

02/12/2015


Semco's Unitary Wheel Cassette (UWC) Series is a latent energy recovery aluminum desiccant wheel that is designed and packaged as an HVAC drop-in replacement for polymer desiccant wheels in most unitary ERV brands. Courtesy: SemcoSemco's Unitary Wheel Cassette (UWC) Series is a latent energy recovery aluminum desiccant wheel that is designed and packaged as an HVAC drop-in replacement for polymer desiccant wheels in most unitary ERV brands. The UWC Series' 3.75-in.-wide wheels feature a fast-acting, corrosion-resistant, proprietary desiccant that's applied to a sturdy, but lightweight all-aluminum wheel substrate. The honeycomb matrix's fluted opening design efficiently produces maximum latent and sensible air-to-air heat transfer, but generates up to 50% less HVAC system static pressure than polymer film wheels. All UWC Series models are packaged as plug-and-play cassettes that include the industrial-duty inverter motor, corrosion-resistant rotor, and industrial-grade link drive belt. Other benefits include a temperature differential between wet bulb/dry bulb exhaust. Controls are compatible with building automation systems (BAS).

Semco

www.semcohvac.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me