Alloy water heaters

PVI Industries' water heaters are manufactured from AquaPLEX, which allows water to be stored at greater than 200 F continuously without effect.

10/12/2011


PVI Industries’ water heaters and storage tanks are manufactured from AquaPLEX, an engineered duplex alloy with 21% chromium content. AquaPLEX combines the grain structures of both 300 and 400 series stainless steels, offering the benefits of both and exceeding the corrosion resistance of either material alone. Tanks made from AquaPLEX require no lining or anode rods of any type. Water can be stored at greater than 200 F continuously without effect. After the tank is fabricated and welding is completed, the AquaPLEX material is completely immersed in a pickling and passivation bath. This process imparts a passive chromium layer on the tank surface that is highly resistant to general aqueous corrosion. Additionally, the product is resistant to chloride stress corrosion cracking. AquaPLEX is approved by the ASME code for water heater fabrication, making it a nonproprietary tank material. Water heaters and storage tanks are available with capacities of up to 900 gallons with gas, oil, electric, steam, or boiler water as the energy source.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me