Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project

Addition to existing building: Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project; CDM Smith

Source: CDM Smith

08/09/2012


A cogeneration unit is set in place during construction. Courtesy: CDM Smith (Click to enlarge)Project name: Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project

Location: Menands, N.Y.

Firm name: CDM Smith

Project type, building type: Addition to existing building, manufacturing

Project duration: 4 years

Project completion date: Dec. 1, 2012

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $870,000

Engineering challenges

Issues related to this project included ensuring that the equipment would meet all applicable U.S. standards for the interconnection with the utility, ensuring that the plant personnel were comfortable operating the equipment, and helping the owner secure funding to move the project forward.

Solutions

The CDM-led team was hired to independently evaluate and determine the feasibility of utilizing the high-temperature (1,000 to 1,250 F) exhaust gas flow from the incinerators to an organic rankine cycle system and drive a turbine generator. The CDM team also provided support to the Albany County Sewer District for an application to the New York State Energy Research and Development Authority (NYSERDA), which led to a grant for up to $2 million in engineering and construction funding. Additionally, the CDM team provided support to the district for an application to the New York State Environmental Facilities Corporation (NYSEFC), which led to a $5.8 million in Green Innovation Grant Program (GIGP) funding. Results of the study predict the waste heat from the incinerators is expected to co-generate 3.3 million kWh per year (enough to power 3,000 households); reduce the district’s natural gas consumption by 100,000 therms per year, for a value of $475,000 annually at present rates; and reduce greenhouse gases by 1,445 tons/year. In addition, thermal energy reclaimed will be utilized for space heating, creating a combined heat and power (CHP) system.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.