6 mm universal signal conditioner has auto-reset fuse

Wago Corporation's 6 mm universal signal conditioner offers signal precision, an auto-reset fuse, and signal clipping, the company said.

08/17/2011


Wago Corporation's 857-402 Jumpflex Universal Signal Conditioner (USC) supports 456 signal combinations with exclusive input voltage range and self-resetting fuse. Courtesy: WagoWago Corporation's 857-402 Jumpflex Universal Signal Conditioner (USC) supports 456 signal combinations with exclusive input voltage range and self-resetting fuse. Unlike competitive 12.5 mm devices, the 6 mm USC offers class-exclusive signal clipping and freely scalable voltage input range — ±60 mV to a segment-leading ±200 V. Current input range is ±0.3 mA to ±100 mA.

Constant signal precision

DIP switch configurable, the USC’s 456 signal combinations reportedly maintain precise, constant values — even after reconfiguration — via factory-calibrated, laser-capable resistors. 857-402 replaces the traditional screw potentiometer with an innovative, vibration-proof momentary rocker-style switch (MRS). The MRS has no end/stop point for signal settings/adjustments and provides scalability across entire measurement range.

Auto-reset fuse

857-402’s Auto-reset Fuse protects current input against overloads without impacting input value; fuse automatically resets after overload removal.

Signal clipping:

The USC’s signal clipping feature safeguards PLCs by switching between limiting and analog behavior. Example: if a transducer’s input exceeds 20 mA, the output signal is clipped at 20 mA. This ensures output will continue functioning properly, preventing errors.

857-402 is said to incorporate Jumpflex features, including: flexible color-coded, push-in jumpers, jumper slots at every connection point, one marking tag holder, ribbon cable interface adapter, 3 way 2.5kV isolation and Cage Clamp S termination technology. The USC’s operating temperature range is -25 C to +70 C.

Wago Corporation

www.wago.com  

- Edited by Chris Vavra, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me