4-quadrant positioning motion controller
Dunkermotoren USA's motion controller is designed to control brushless and brushed DC motors through CANopen networks or as a standalone with digital and analog I/O.
A 4-quadrant positioning motion controller with integral output stage is available from Dunkermotoren USA. It is designed to control brushless and brushed DC motors as a slave in widely used CANopen networks or in stand-alone operation with digital or analog I/O.
Two versions of the new control are available in the same compact, power-dense package size of 51.7cc, slightly larger than a matchbox. The BGE 3508 model is designed for 10-30 Volt input with 75 W of continuous and 225 W peak power, while the BGE 6005model can produce 120 W continuous and 300 W of peak power with 60 Volt input.
These new controllers are suitable for use with brushless or conventional brushed dc motors similar to Dunkermotoren’s BG and GR/G ranges. Information about the motor’s rotor position can be supplied to the positioning controller either by the voltage or by an encoder in the case of commutator motors or, for brushless motors, by Hall sensors or an incremental encoder. The controls incorporate protection against over-voltage, low voltage and excessive temperature.
If 4-quadrant digital speed control is desired, the control can be commanded to run in either direction, stop and hold with torque, and stop without torque (coast) through digital inputs. Other inputs can switch between programmed speeds or allow for a v ariable analog speed reference. Accel/decal ramps for the motor can also be programmed. The control reportedly offers the capability for a motor to function as a stand-alone, programmed servo which interfaces to the rest of the machine via digital and analog I/O.
The new BGE 3508/6005 controllers reportedly offer many different modes of operation to choose from, such as analog or digital torque control, analog or digital speed control and digitally selectable position control (relative, absolute, and modulo).
"The CAN bus functionality of this drive makes it a powerful tool in industrial applications, allowing decentralized control and a reduction in complexity of the overall system," said Jonathan Doyle, applications engineer, Dunkermotoren USA.
Designed for volume OEM applications, the Dunkermotoren BGE 3508/6005 controllers offer a design alternative for restricted space applications where the additional length of an integral control motor may not be feasible. They can also be encapsulated to provide additional protection in extreme environmental conditions.
CANopen is the most widespread application layer in non-automotive control applications and market researchers predict that by 2015 some 400 million CAN chips will be used annually in a wide range of applications such as medical equipment, heavy vehicles, door control systems and throughout commercial and industrial automation systems.
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.