2D optical micrometer
The TM-3000 2D Optical Micrometer from Keyence is designed to combine the functionality of a laser scan micrometer, machine vision system and optical comparator into one device.
The Keyence TM-3000 2D Optical Micrometer introduces significant technological advancements to 100% automated high-speed, in-line or off-line measurement and inspection applications. The TM-3000 is designed to combine the functionality of a laser scan micrometer, machine vision system and optical comparator into a single device. It is available in three sensor head sizes along with the ability to use 2 transmitter-receiver pairs simultaneously to provide flexibility.
2D micron measurement precision
The 2D Optical Micrometer employs a dual telecentric lens to create uniform collimated light with a green LED. A two dimensional CMOS array then detects the light to dark transitions on the 2D array to measure the dimensions. Certificates of traceability along with calibration certificates are available upon request. High speed and high precision are a result of sub-pixel processing only in the areas or points designated for measurement.
Multi-Point measurement with no target positioning required
Because the system works in two dimensions it can measure up to 16 points within the measurement area. A combination of 15 measurement modes and 8 auxiliary modes can support measurements including, but not limited to, hole diameter, center pitch, intersection point, radius, width, angle, perpendicular distance and area. The position correction function automatically orients the test part prior to measurement, thus increasing accuracy. No longer are expensive positioning mechanisms needed to ensure the best precision. All programming and monitoring can be performed with or without a PC.
Keyence Corporation of America
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.