2011 POY Finalists: Test Instruments, Meters, Data-loggers

Finalists in Test Instruments, Meters, and Data-loggers in Consulting-Specifying Engineer's 2011 Product of the Year competition

05/09/2011


Laser distance measurer

The GLR825 laser distance measurer by Bosch Measuring Tools can measure in 11 different modes for distances up to 825 ft and is accurate to within 1 mm. The instrument offers users the flexibility of measuring from one of four distinct points, including a multifunctional extension pin. The tool has enough built-in memory to store up to 30 results. The product has a 1.6 times magnification viewfinder for precision laser sighting in long-range or outdoor applications. A glass lens and ceramic optics carrier provide maximum durability, and the unit is IP54 protected against dust and water.

www.boschtools.com


Vibration tester

The 810 Vibration Tester by Fluke allows large commercial facility teams to test large capital equipment such as chillers, compressors, and large motors. The tester can assess the equipment’s mechanical health and use vibration to detect mechanical problems while they are still easy and affordable to fix. Previously, this required hiring a consultant or installing a monitoring system. The onboard database of the 810 can evaluate specific equipment models, compare the vibration signals to a comprehensive database sourced from years of monitoring in military facilities, and provide a health analysis, diagnosis, and recommendation for any problems it detects.

www.fluke.com


Thermal imaging scanner

Fluke’s TiS Thermal Imaging Scanner is designed for retrofit and new construction analysis done by engineers who use thermal imaging to detect flaws in construction, such as the common problems of air gaps from faulty insulation and window/door installs. By sensing minute differences in temperature and using color to create a thermal picture of those differences, a buildings expert can immediately detect structural flaws. The TiS has a large screen and features like manual focus that allow the user to capture multiple kinds of shots and angles. It provides complete thermal temperature data for every pixel on screen.

www.fluke.com


Labeling system

K-Sun Corp.’s Green Machine Labeling System is a label, heat-shrink tube, and bar-code thermal-transfer printer system for professional, pressure-sensitive labels. The product runs on standard AA batteries or an international ac adapter; advanced features include a large, high-intensity backlit display. It has hot keys for making patch-panel, wire-wrap, or flag labels for wire and cable identification. Combined with the company’s MaxiLabel Pro Ver. 3.0 software, the product can create hundreds of ANSI safety, industrial, and general symbols, and it has the ability to easily import custom images. Add-on symbols libraries include laboratory/medical, electrical, and homeland security.

www.ksun.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me