Upcoming Webcast: Understanding Generator Set Rating Definitions

Nicholas Paolo

  Featured presenter: Nicholas Paolo, PE, Regional Sales Engineer, MTU Onsite Energy

Understanding Generator Set Rating Definitions

Thursday, March 2, 2017, at 11 a.m. PT/1 p.m. CT/2 p.m. ET

Attendees qualify for a Certificate of Completion
#MTUpower

 

This presentation is designed to educate consulting specifying engineers regarding the various factors that influence a generator set's ratings, and how familiarity with these factors can contribute to more economical and reliable facility designs. The presenter will discuss ISO standards for generator sets rated for use in standby, prime and continuous power applications. The speaker will consider flexibilities that generator set manufacturers use when rating their products—such as net power output vs gross power output—and their implications in terms of generator performance.

During this webcast, the presenter will compare various starting methods including across the line start and soft start solutions. EPA exhaust emission requirements will be examined, and the presenter will compare and contrast their implications in emergency, non-emergency and mobile applications. Specific industry ratings, such as data centers, will be reviewed and considered, including the implications when specifying generator sets.


Learning objectives:

  • Overview of the ISO (International Standards Organization) 8528-1 and EPA (Environmental Protection Agency) emergency and non-emergency regulations for generator set ratings.
  • Understanding of manufacturer allowances and their implications in terms of generator set ratings.
  • Comprehension of EPA exhaust emissions requirements and their implications in emergency, non-emergency and mobile applications.
  • Familiarity with specific industry ratings, such as data centers.

Featured Speaker: Nicholas Paolo, PE, Regional Sales Engineer, MTU Onsite Energy

Nicholas Paolo, PE, is a Regional Sales Engineer for MTU Onsite Energy, a Rolls-Royce Power Systems brand. He holds a Bachelor of Science in Mechanical Engineering, an MBA from Minnesota State University and also a Professional Engineering License. Paolo has a background in application engineering at MTU Onsite Energy designing generator sets up to 3250 kWe, recently transitioning into sales engineering, assisting distributors in the United States and Canada on custom power generation projects. He is an active member of IEEE, ASME, MNSPE, AFCOM, 7x24 and EGSA.

Moderator: Jack Smith, Content Manager, Consulting-Specifying Engineer, CFE Media

CLICK HERE TO REGISTER NOW