Variable frequency drive cables support large horsepower motors

Belden introduces MCM VFD cables to support large horsepower motors.

Source: Belden

06/22/2012


Belden, provider of signal transmission solutions for mission-critical applications, announced the extension of its line of variable frequency drive (VFD) cables to include 250 MCM, 350 MCM and 500 MCM sizes. MCM VFD cables support installations of up to 250 horsepower motors at 460 V for use in oil and gas, petrochemical, power generation, water and wastewater treatment and other demanding industrial environments.

Belden MCM VFD cables are rated for use in exposed-run cable trays, direct burial and in wet or dry conditions. Belden’s MCM VFD cables are said to be designed to provide superior performance in noise-sensitive applications or in any damp or wet environment where reflected wave voltages may degrade PVC/nylon conductors. The cable is suitable for use with virtually all variable frequency drives, as well as for use as shielded power cable for other solid-state devices.

Electrical performance, reliability for VFD applications

VFDs reduce facility energy consumption and thus operating costs; however, VFDs can be a significant source of noise, most particularly electromagnetic interface (EMI), in a facility. In addition, VFDs are usually operated in close proximity to sensitive instruments, critical networks and safety systems. Proper cable selection from cables specifically designed to connect to VFDs can mitigate adverse effects on nearby cable systems and reduce the likelihood of cable or motor failure.

The design of Belden’s MCM VFD cables are said to provide superior common mode current protection and help protect a system against damage from reflected wave voltages and capacitively coupled current for maximum safety and reliability. Design features of Belden MCM VFD cables include symmetric bare grounds, dual copper tape shield, enhanced XLP insulation, industrial-grade PVC jackets for longer life and a TC-ER (Exposed Run) rating that allows cable to run from cable tray to point of utilization per the NEC to reduce the need for additional support or protection.

Ratings

Belden’s MCM VFD cable carries the following ratings:  2000 V UL 1277 Type TC-ER per 2005 NEC Article 336, 1000V CSA TC C22.2 No 230, 90 ⁰C wet/dry, Class I & II, Div. 2 hazardous locations, UL 1685 vertical tray flame test, FT4, IEEE 1202 vertical tray flame test at 70,000 BTU/hour. The cable is rated UL direct burial, oil and sunlight resistant, RoHS compliant and CE approved.

- Edited by Control Engineering, CFE Media

Find other industrial networking products at controleng.com/networks



No comments

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.