Local Area Lingo: A Turn-of-the-Century Controls Glossary

Control network: A collection of DDC microcontrollers distributed throughout a facility that use a control protocol and one or more network media to communicate. Control protocol: An electronic language spoken between microcomputer-based DDC controllers to pass values and commands.

By Consulting Specifying Engineer Staff

02/01/2001


Control network : A collection of DDC microcontrollers distributed throughout a facility that use a control protocol and one or more network media to communicate.

Control protocol : An electronic language spoken between microcomputer-based DDC controllers to pass values and commands.

Direct-digital control (DDC): An automated control scheme using microcomputers connected to electronic sensors and actuators.

Distributed control : Automated control using microcomputer-based controllers distributed on a control network throughout a facility. Each microcontroller in a distributed system has local "intelligence" or logic capability and also communicates via a control protocol to other microcontrollers on a control network over one or more network media.

Gateway : A hardware or software device that translates from one control protocol to another.

Hierarchical control network : A method of building control networks where parent controllers manage small subnetworks with fixed numbers of controllers under a given parent device.

Media converter : A device used to move from one network media to another.

Microcontroller : A microcomputer with local logic capability as well as sensory input and actuator outputs used in a distributed control network .

Network media : The physical method of transmission of a control protocol . Examples include radio frequency, power-line carrier, infrared light and various wiring schemes such as Ethernet, twisted-pair and serial connections.

Parent controller : A logic device used in hierarchical control networks to manage a fixed number of smaller devices. Typical hierarchal implementations use this controller also as a gateway or media converter .

Peer-control network : A control network in which any device can communicate to any other device without the need to pass through a parent controller or gateway .

Plug-in : A small, device-specific software application or wizard provided by a manufacturer intended to add value to the product.

TCP/IP : The acronym for transmission-control protocol\Internet protocol, the common underlying protocol spoken by all devices and applications on the Internet.





No comments

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.