SEARCH Archives
Loading
Sponsored by:

Better security through math

Statistical databases (SDBs) are collections of data used to gather and analyze information from a variety of sources. The data may come from plant floor computations, sales transactions, customer files, voter registrations, medical records, employee rosters, product inventories, or other compilations of facts and figures.

Gregory Hale, ISSSource

01/31/2012


ISSSourceStatistical databases (SDBs) are collections of data used to gather and analyze information from a variety of sources. The data may come from plant floor computations, sales transactions, customer files, voter registrations, medical records, employee rosters, product inventories, or other compilations of facts and figures.

Because database security requires multiple processes and controls, it presents huge challenges to organizations. With the computerization of databases in manufacturing, healthcare, forensics, telecommunications, and other fields, ensuring this kind of security has become important and will become even more crucial in the coming years.

Along those lines, there is now a security-control model for statistical databases.

“Providing privacy and confidentiality in SDBs is not a new issue,” said Harout Aydinian of the Bielefeld University in Germany who wrote a paper on the subject with the late Rudolf Ahlswede. “Privacy interests have evolved from the very first census in the United States. Recorded protests until the mid-20th century reflect constitutional issues resulting from the requirement for U.S. residents to provide sensitive personal information. Questions on census forms about diseases, mortgage values, and other items have raised many concerns.”

While such databases are very helpful in aggregating data, there is a risk that confidential information about an individual’s record may end up deliberately compromised.

“Since such data sets also contain sensitive information, such as the disease of an individual, or the salary of an employee, it is necessary to provide security against the disclosure of confidential information,” Aydinian said. “Even in cases where a user has no direct access to sensitive information, sometimes confidential data about an individual can be inferred by correlating enough statistics.”

Typically, statistical databases only accept queries that involve specific statistical functions (such as sum, average, count, min, max, etc.). However, the use of these queries may render databases susceptible to compromise. For instance, it may be possible to infer information about specific individuals by putting together data from a sequence of statistical queries, using prior knowledge of an individual, or through collusion among users.

An SDB is secure if no one can infer protected data from available queries.

“In the literature, many scenarios of compromise and inference control methods have been proposed to protect SDBs,” Aydinian said. “However, to date no one security control method is capable of completely preventing compromise.”

Query restriction is one of several general approaches used for security control. A “query request” retrieves a subset of data from a database that meets a set of conditions. In query restriction, there are limits on the kind and amount of data you can retrieve.

In one type of query restriction method, only certain sums of individual records (called “SUM queries”) that meet a minimum specified size or number, and satisfy a specified set of conditions, are available to users.

“Consider a company with a large number of employees,” Aydinian said. “Suppose that for each member of the company, the sex, age, rank, length of employment, salary etc. is recorded. The salaries of individual employees are confidential. Suppose that only SUM queries are allowed, i.e. the sum of the salaries of the specified people is returned. Then one might pose the query: What is the sum of salaries for males, above 50, and during the last 10 years?”

The researchers provide an optimal collection of SUM queries that prevents compromise of confidential information — such as individual salaries, for instance. A natural solution is to maximize the number of available SUM queries. The authors obtain tight bounds for the maximum number of such queries that return subsets of data without compromising groups of entries.

“Future work in the query-restriction approach includes evaluation of new security-control mechanisms, which are easy to implement and guarantee absolute security,” Aydinian said. “At the same time, it is desirable that these methods satisfy other criteria like richness of available queries, consistency, cost etc. It also seems promising to develop methods combining different security control mechanisms.”



No comments

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.