Geothermal heat pump

The Envision2 Compact Series by WaterFurnace International is available in 3/4- to 6-ton capacities.

04/08/2013


Envision2 Compact Series by WaterFurnace International Inc.The Envision2 Compact Series by WaterFurnace International is available in 3/4- to 6-ton capacities. It incorporates a number of features including a factory-installed 24 V motorized on-off water valve for VFD pumping with automatic internal water flow control; hot gas bypass and reheat; and high-efficiency PSC, five-speed ECM, or variable speed ECMs. Single-speed models operate with a Copeland 5-K Scroll or LG rotary compressor, while dual-capacity units use a Copeland UltraTech compressor. All Envision heat pumps feature coaxial heat exchangers with a copper inner tube and steel outer tube for maximum heat transfer at normal and low water flow rates, minimizing pressure drop.

WaterFurnace International Inc.

www.waterfurnace.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
MEP Giants; MEP Annual Report; Mergers and acquisitions; Passive, active fire protection; LED retrofits; HVAC energy efficiency
Integrating electrical and HVAC systems; Tracking and conserving facility water use; Energy code advancements; The future of professional engineers
Control noise, vibration in building design: Tackling acoustics and design issues; High-performance building design; NFPA 99; Combined heat, power
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
Designing generator systems; Using online commissioning tools; Selective coordination best practices
Understanding transfer switch operation; Coordinating protective devices; Analyzing NEC 2014 changes; Cooling data centers
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me