System-level control for parallel genset operations

The DMC 1500 PowerCommand Paralleling System combines Cummins Power Generation’s microprocessor-based control technology with a new icon-based graphical user interface designed to maximize user-friendliness.

04/08/2013


DMC 1500 Paralleling System Cummins Power The DMC 1500 PowerCommand Paralleling System combines Cummins Power Generation’s microprocessor-based control technology with a new icon-based graphical user interface designed to maximize user-friendliness. The system consists of a PowerCommand system-level digital master control integrated with custom-engineered switchgear. The DMC 1500 communicates with the PowerCommand generator set and transfer switch controls for seamless integration. DMC 1500 systems can also be used for prime power at remote locations. Power transitions can be open or closed, in either fast (100 ms) or gradual ramping mode. The system includes utility paralleling functions for peak-shaving, base-loading, and load add/load shed sequence control.

Cummins Power Generation

www.cumminspower.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
MEP Giants; MEP Annual Report; Mergers and acquisitions; Passive, active fire protection; LED retrofits; HVAC energy efficiency
Integrating electrical and HVAC systems; Tracking and conserving facility water use; Energy code advancements; The future of professional engineers
Control noise, vibration in building design: Tackling acoustics and design issues; High-performance building design; NFPA 99; Combined heat, power
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
Designing generator systems; Using online commissioning tools; Selective coordination best practices
Understanding transfer switch operation; Coordinating protective devices; Analyzing NEC 2014 changes; Cooling data centers
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me