Switchboard line

The Evolution Series Switchboard line by General Electric is designed for critical power applications such as high-rise hotels and casinos, hospitals, airports, and universities.

04/09/2013


Evolution Series Switchboard line by General Electric The Evolution Series Switchboard line by General Electric is designed for critical power applications such as high-rise hotels and casinos, hospitals, airports, and universities. Featuring innovative instantaneous zone-selective interlocking (I-ZSI) and waveform recognition (WFR) technologies, the Evolution Series Switchboard provides users with an unparalleled, industry-first combination of full selective coordination and simultaneous arc flash protection. GE’s new Evolution Series Switchboard no longer requires building managers to sacrifice arc flash protection for selectivity. When responding to a fault, the Evolution Series Switchboard has the intelligence to tell circuit breakers to respond either immediately or as a backup, depending on the situation.

General Electric

www.ge.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
MEP Giants; MEP Annual Report; Mergers and acquisitions; Passive, active fire protection; LED retrofits; HVAC energy efficiency
Integrating electrical and HVAC systems; Tracking and conserving facility water use; Energy code advancements; The future of professional engineers
Control noise, vibration in building design: Tackling acoustics and design issues; High-performance building design; NFPA 99; Combined heat, power
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
Designing generator systems; Using online commissioning tools; Selective coordination best practices
Understanding transfer switch operation; Coordinating protective devices; Analyzing NEC 2014 changes; Cooling data centers
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me