Photovoltaic fuses

The 1500 Vdc photovoltaic fuse line by Cooper Bussmann permits OEMs to design efficient solar power systems.

04/08/2013


1500 Vdc photovoltaic fuse line by Cooper BussmannThe 1500 Vdc photovoltaic fuse line by Cooper Bussmann permits OEMs to design efficient solar power systems. With UL, IEC, and CCC approvals, the entire line permits designers to create systems that are globally accepted. PV system manufacturers can select from sizes ranging from a 14- x 65-mm ferrule fuse to four square body XL sizes, with ampacities from 15 to 400 A. Designed specifically to protect and isolate PV array combiners and disconnects, these high-performance fuses are capable of interrupting low overcurrents associated with faulted PV systems, such as reverse current and multi-array faults.

Cooper Bussmann

www.cooperbussmann.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me