SEARCH Archives
Loading
Sponsored by:

Wireless instrumentation monitors water usage at pharmaceutical plant

GlaxoSmithKline uses Rosemount wireless pressure and flow transmitters; provides network for future expansion.

SOURCE: Emerson Process Management

04/20/2011


Emerson Process Management’s Smart Wireless technology is enabling GlaxoSmithKline to monitor water usage at its Cork plant in Ireland. Installation of Rosemount wireless flow and pressure transmitters on two new storage tanks has provided an opportunity to understand water usage throughout the plant in greater detail, to test wireless instrumentation technology, and to create wireless network infrastructure for new process instrumentation in the future.

“GlaxoSmithKline is continuously looking to improve plant performance by increasing the number of parameters measured,” explained Emmett Martin, site services and automation manager, GlaxoSmithKline. “Water is a considerable overhead to the plant so it is important that we monitor flow rates to manage consumption, and to help identify any usage trends.”

The Cork site is a strategic manufacturing plant that produces a range of bulk active ingredients for use in the formulation of prescription drugs. The existing water storage facility was too small and had no measurement instrumentation in place. Two new storage tanks were installed along with new piping infrastructure. The tanks are located around 300 m from the main control room and there was no existing cabling in place. A wired installation would have required new power and data cables to be buried in trenches. By adopting a wireless solution these significant costs were avoided.

Ten Smart Wireless devices were installed, including six Rosemount pressure transmitters, two Rosemount flow transmitters, and two Rosemount level transmitters. The wireless technology integrates seamlessly with the existing automation equipment. Flow data is transmitted every 30 seconds and pressure and level data every 300 seconds to a Smart Wireless Gateway strategically positioned on the control room roof. This is connected using a serial connection to the existing DeltaV digital automation system that controls the plant utilities. From here the flow and pressure measurements are sent to a data historian and are available to plant operators for regular monitoring and reporting.

The new data obtained has enabled GlaxoSmithKline to identify water usage clearly for different areas of the plant, providing a better understanding of the costs and a mechanism to identify changes.

The new wireless infrastructure makes it very easy and cost effective to add additional measurement devices without the need for new cabling. GlaxoSmithKline is already looking at installing a wireless level device that will be added to the existing network.

“We regard the installation of wireless very much as a two stage process,” explained Martin. “The first step is to establish a wireless network and let it prove itself over a period of time. The next step is to expand the network and use wireless whenever it is more cost effective than a wired alternative. We are more than satisfied with the solution, which is proving to be reliable with no signal loss. Based on a successful implementation, at some point in the future we are perhaps, looking towards a plant with no wires.”

www.EmersonSmartWireless.com

www.EmersonProcess.com

Visit the Control Engineering Process Control Channel.

Edited by Peter Welander, pwlenader(at)cfemedia.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.