Wago X-Com S pluggable terminal block connectors
Wago Corp.’s new 2020 and 2022 Series X-Com S Pluggable Connector Systems merge touchproof, pre-wired assemblies with Topjob S terminal blocks. Wago X-Com S combines pluggable connectors, DIN-rail blocks and Cage Clamp S connections to streamline and eliminate wiring errors during panel- and machine-building.
Wago Corp.’s new 2020 and 2022 Series X-Com S Pluggable Connector Systems merge touchproof, pre-wired assemblies with Topjob S terminal blocks. Wago X-Com S combines pluggable connectors, DIN-rail blocks and Cage Clamp S connections to streamline and eliminate wiring errors during panel- and machine-building.
Prior to machine shipment, Wago X-Com S simulates field wiring for machine testing, then provides fast, error-free wiring for re-assembly at the end-location. During final install, the system provides PLC-to-terminal block wiring and pluggable connections for cabinet door accessories, such as push-buttons, to terminal blocks.
Wago X-Com S shares a common profile with Topjob S terminal blocks — which is up to 30% more compact than other blocks — and accessories including jumpers, test plugs and marking, the company says. The new system provides simple push-in termination for solid or ferruled conductors; for other types, a screwdriver opens the clamping unit for insertion. Upon install, ground (earth) X-COM S models automatically make contact with the DIN-rail.
The terminal blocks are available in single- or double-deck configurations with 3.5 mm or 5.2 mm pin spacing; modular female plugs are available in 1- and 2- Conductor entries up to 15 poles. 1-conductor/1-pin, 2-conductor/1-pin, 2-conductor/2-pin and ground (earth) blocks are also available.
Wago spring pressure connection technology eliminates loose wires resulting from vibration and temperature cycling, while providing highly reliable, corrosion-resistant and maintenance-free connections, the company says. Products include DIN-rail, PCB and chassis mount terminal blocks; signal conditioners; the Wago-I/O-System; and others.
Also see:
Protocol compatibility, multiple I/O types: Wago
Wago 4-Channel Electronic Circuit Breakers
- Edited by Mark T. Hoske, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.
Click here to visit the Case Study Database and upload your case study.