Visual IR thermometer

The Fluke VT04 Visual IR Thermometer is a troubleshooting tool designed for electrical, industrial maintenance, and HVAC/R applications.

03/20/2014


The Fluke VT04 Visual IR Thermometer is a troubleshooting tool designed for electrical, industrial maintenance, and HVAC/R applications. Courtesy: FlukeThe Fluke VT04 Visual IR Thermometer is a troubleshooting tool with built-in digital camera and thermal heat map overlay that bridges the gap between traditional IR thermometers and infrared cameras. It is designed for electrical, industrial maintenance, and HVAC/R applications. The Fluke VT04 is fully automatic with built-in intelligence, so issues can be detected instantly with no training required. The VT04 includes advanced alarm features for troubleshooting stubborn intermittent issues, including a high-low temperature alarm that flashes on the screen if the user-selected temperature goes out of the selected range. It also has a time-lapse image capture that can be set to capture images in 30-sec to 1-hour intervals, and an auto-monitor alarm that initiates image capture after a temperature alarm has been triggered, allowing users to automatically capture images. A temperature reading is provided at the center point. Images are saved to the included micro-SD card, eliminating the need to write down single or multiple measurements. The VT04 Visual IR Thermometer also has a rechargeable Li-ion battery.

Fluke Corp.

www.fluke.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me