UPS for large data center applications

Mitsubishi Electric's one megawatt (1.05 MVA) 9900C UPS is an on-line double conversion UPS that is scalable up to eight units for N+1 redundancy or N capacity and incorporates Digital Signal Processor and Direct Digital Control (DDC).

06/04/2014


Mitsubishi Electric's one megawatt (1.05 MVA) 9900C UPS is an on-line double conversion UPS that is scalable up to eight units for N+1 redundancy or N capacity and incorporates Digital Signal Processor and Direct Digital Control (DDC). Courtesy: MitsubishMitsubishi Electric's one-megawatt (1.05 MVA) 9900C UPS is an on-line double conversion UPS. The 9900C three-phase UPS delivers up to 97% efficiency, which substantially reduces operation and cooling costs, making it ideal for large data center applications. It is scalable up to eight units for N+1 redundancy or N capacity. 

The 9900C incorporates Digital Signal Processor and Direct Digital Control (DDC) in order to achieve the full benefits of Insulated Gate Bipolar Transistors (IGBTs) and the three-level conversion design increases capacitor life for the UPS.

For additional ease-of-use, the 9900C provides a variety of open architecture communications methods as well as an intuitive LCD touch panel to quickly access system status, monitoring and control.

Mitsubishi Electric Automation Inc.

www.meau.com 

- Edited by CFE Media. See more Control Engineering energy and power stories.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me