System-level automation software

Johnson Controls launched the Central Plant Optimization system-level automation software, a holistic approach to designing, installing and operating, for maximum efficiency in chilled water plants.

02/07/2011


Johnson Controls announced the Central Plant OptimizationT10 (CPO 10) and Central Plant OptimizationT30 (CPO 30) to help reduce energy consumption in central chilled water plants in buildings by up to 60 percent. This new system-level automation software enables persistent peak performance and energy savings in central plants in both new construction and existing buildings.

Sample CPO 30 dashboard screens for operating cost differential and operating efficiency. Dashboards allows users to monitor plant performance and operating efficiency on a real-time basis. Source: Johnson ControlsDepending on climate, region and equipment configurations, a central chilled water plant can consume more than 30 percent of the power required to run a building. To achieve peak efficiency performance, a facility's central plant equipment and independent components can now be designed and operated as a single integrated system with Johnson Controls Central Plant OptimizationT software.

Traditionally, energy efficiency in the heating, ventilation and air-conditioning (HVAC) industry has been driven by the capabilities of individual components. Central Plant Optimization offers a holistic system approach with the potential to achieve and sustain ongoing savings throughout the entire lifecycle of an HVAC system.

Both CPO 10 and CPO 30 feature innovative control technologies that are designed to provide system performance improvements based on real-time building loads. When incorporated with a modern building automation system and efficient HVAC equipment, CPO software solutions can help a chilled water plant system achieve maximum energy savings.

Central Plant Optimization 10 (CPO 10)

Johnson Controls CPO 10 maximizes a facility's HVAC system and equipment performance by selecting the most efficient combination of pumps, chillers and cooling towers needed to meet building cooling load. Ideal for new construction projects as well as upgrades to existing buildings, CPO 10 works with virtually all types of central plants and can achieve up to 15 percent in energy savings over a standard automation approach in an otherwise identical plant.

  • Powered by the Johnson Controls MetasysR building management system, CPO 10 leverages proven, tested and documented logic and standard programs to control the sequencing of pumps, isolation valves and chilled water plant equipment, while maintaining the timing delays for safe and stable operation.
  • To monitor plant operation, the Metasys Ready Access Portal provides customized and easy-to-access plant operating information via standard browsers and Apple iPhoneR and iPodR Touch platforms.
  • Metasys Energy Essentials reporting enables visibility of energy use, including equipment runtime, starts and stops, energy consumption and energy cost details, weather details and daily load profiles, helping to monitor plant performance over time.

Central Plant Optimization 30 (CPO 30)

Johnson Controls Central Plant Optimization 30 (CPO 30) powered by OptimumHVACT incorporates a software application from Optimum Energy that continuously optimizes central chilled water plant operation to achieve peak energy efficiency and performance. Central to CPO 30 is patented relational control technology that makes it possible to operate variable speed central plants holistically based on the power relationships between each piece of equipment and real-time cooling load conditions. When combined with CPO 30's built-in measurement, verification and management services, CPO 30 is proven to provide stable, reliable and persistent energy reductions of 20 to 60 percent in existing plants when coupled with plant upgrades.

  • The CPO 30 software application is platform neutral for seamless integration with virtually any building automation system (BAS), including Metasys, Johnson Controls building management system.
  • Every 30 seconds, the software automatically gathers current operating and building load data from the BAS. The application then applies relational control algorithms to calculate optimal system operation, and directs control sequences back to the BAS for execution.
  • Web-based measurement, verification and management services provide system operators the information they need to sustain energy reductions. Graphs and charts make it simple to track real-time energy use, manage system operations and find and correct system faults as they occur.

For more information about Johnson Controls Central Plant Optimization and Metasys 5.1 building management system, visit http://www.johnsoncontrols.com/CPO.

- Edited by Amanda McLeman, Consulting-Specifying Engineer, www.csemag.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Water use efficiency: Diminishing water quality, escalating costs; Lowering building energy use; Power for fire pumps
Building envelope and integration; Manufacturing industrial Q&A; NFPA 99; Testing fire systems
Labs and research facilities: Q&A with the experts; Water heating systems; Smart building integration; 40 Under 40 winners
Maintaining low data center PUE; Using eco mode in UPS systems; Commissioning electrical and power systems; Exploring dc power distribution alternatives
Protecting standby generators for mission critical facilities; Selecting energy-efficient transformers; Integrating power monitoring systems; Mitigating harmonics in electrical systems
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.