Sports, entertainment venues: Sustainability and energy efficiency

Sports arenas and entertainment facilities involve complex engineering solutions. Engineers discuss sustainability, renewable energy, and energy efficiency in these buildings.

04/24/2013


Keith Cooper, PE, President, McClure Engineering, St. Louis. Courtesy: McClure EngineeringDouglas H. Evans, PE, FSFPE, Fire Protection Engineer, Clark County, Nevada. Courtesy: Clark County, NevadaBill Larwood, PE, LEED AP, Senior Vice President/Project Principal, Syska Hennessey Group, Los Angeles. Courtesy: Syska Hennessey GroupKevin Lewis, PE, LEED AP BD+C, Vice President, Henderson Engineers, Lenexa, Kansas. Courtesy: Henderson EngineersBruce McKinlay, Principal, Arup, Los Angeles. Courtesy: Arup

Participants (left to right):

Keith Cooper, PE, President, McClure Engineering, St. Louis

Douglas H. Evans, PE, FSFPE, Fire Protection Engineer, Clark County, Nevada

Bill Larwood, PE, LEED AP, Senior Vice President/Project Principal, Syska Hennessey Group, Los Angeles

Kevin Lewis, PE, LEED AP BD+C, Vice President, Henderson Engineers, Lenexa, Kansas

Bruce McKinlay, Principal, Arup, Los Angeles    


CSE: What types of systems have you specified in stadiums to help make them more efficient?

Larwood: Stadiums and entertainment venues often will have large lobby areas with vast curtain walls—providing great daylighting opportunities. These daylighting solutions rely on light photocells to measure the ambient light and save energy. Likewise, occupancy sensors can save energy throughout the venues by shutting off lights.

McKinlay: I’ve seen passive shading strategies for open arenas, thermal energy storage (TES) so cooling can be generated over low demand times, and rainwater reclamation systems to be used for irrigation and toilet flushing.

The team at Arup helped execute systems at the Singapore Sports Hub, which features a 55,000-seat stadium with a retractable roof that has an LED lighting system, making it the largest programmable LED screen in the world. Courtesy: OakerLewis: For arenas with large occupancies, we specify units with CO2 sensors, energy recovery systems, and enthalpy economizers where it makes sense. For non-bowl systems we’ll use variable air volume (VAV) systems or single-zone VAV so that we can make the most of the time periods when the occupied load isn’t 100%. For baseball parks or stadium suites, we have been integrating variable refrigerant flow (VRF) technologies that provide very efficient condensing units to reduce consumption. We’ve also tried to reduce the lighting wattage below the ASHRAE minimums as well as incorporate low-flow fixtures as much as possible to keep water usage at a minimum.

CSE: What types of renewable energy systems have you incorporated into sports or entertainment venues?

Lewis: We have used photovoltaic systems on a variety of projects as a way to use renewable energy systems in sports and entertainment venues. For the most part these projects typically have large roof expanses or parking lots that are ideal areas to catch the sun while not intruding on the final look of the project.

CSE: Have you seen the demand for electric vehicle charging stations increase in venues like this?

McKinlay: Yes, for a project that we were looking to achieve zero carbon in car trips on game day. Not yet, but this could be a feature of the future.

Lewis: For the first time in 2012 we started seeing a request for two to four specific spaces at sports venues for electric car charging stations. As time passes we believe the need for this type of parking spot will increase both in the number of spots required and the number of venues requesting these amenities.

Cooper: We have not. 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me