Plant engineers continue to demand efficient, affordable, and well supported software. And software suppliers are keeping up with plant engineers' demands. Here's a sampling of recent software offerings plant engineers should find useful.Software tracks employees' timeEmployee Proj Clock software is an employee project time tracking tool.
Staff
Plant engineers continue to demand efficient, affordable, and well supported software. And software suppliers are keeping up with plant engineers' demands. Here's a sampling of recent software offerings plant engineers should find useful.
Software tracks employees' time
Employee Proj Clock software is an employee project time tracking tool. Time is tracked by employee, project, and job code. Reports summarize project time for specified periods. Project costs can then be tracked and maintained through the project management and expense features. It allows multiple people to use the program over a network. Its features include pause and day punches, pause and resume, and offsite capabilities. The software allows entering of time blocks and has a data backup feature. It runs on Windows 95, 98, ME, NT 4.0, and 2000. System requirements are at least a 486 processor with 8 MB of RAM and 4-MB hard disk space.
CyberMatrix Corp., Inc.
Cyber-matrix.com
Circle 358
System controls multiple buildings
Networked Building Systems (NBS) technology is a combination of networking hardware and software systems that permits communication within a building's heating, ventilation, air conditioning, fire alarm, lighting control, and security systems; and/or across multiple building systems into one central location. The networks allow for the integration of building management systems with information technology systems to provide centralized monitoring, control, and management for multiple buildings. Proprietary BACnet control standardizes building automation networking for control via LAN, WAN, or internet.
Cimetrics
cimetrics.com
Circle 359
Program identifies filtration products
inPHorm version 1.5 software is updated to provide customers with quick process filtration information on their PCs. It offers access to more than 4000 filtration products with application descriptions, calculations, cost comparisons, and engineering drawings. It also features an updated product listing, cross-reference database utility with more than 90,000 competitive part numbers, and memory capability that allows users to redo analyses without having to reenter data. It has enhanced retrieving and calculating capability, as well as "what if" process simulation scenarios.
Parker Hannifin Corp.
parker.com
Circle 360
SCADA supports multiple devices
ADVANTECH Studio SCADA software includes graphics, large I/O driver, and math libraries, as well as development and runtime components. It features script language, alarming with e-mail notification, and compatibility with OPC and XML. It allows remote management, programming, and updates through the network; and is compatible with standard web browsers. It also includes multiple networked device and multilanguage runtime support. The software allows reduced downtime by predicting repairs before they are required.
ADVANTECH
advantech.com
Circle 361
CD-ROM includes engineering handbook data
"Designing process weighing systems: Engineering Guides" is a software tool, available on CD-ROM for plant engineers involved with the design of batching and process control systems. It is a compilation of data from engineering handbooks and includes calibration procedures, piping design criteria, applying equipment in hazardous areas, designing for wind and seismic loads, glossary of industrial technical terms, and ISA format engineering specification forms and worksheets. The program presents files in a PDF format so that relevant information can be easily printed. The CD-ROM is compatible with Windows, Mac, Unix, and OS/2 operating systems. It includes the free Adobe Acrobat reader.
Thermo BLH, Inc.
thermoblh.com
Circle 362
Plant performance monitor integrates information
Results Point provides a real-time plant monitoring tool using online analytical processing of comparative data (OLAP) originating from Mainsaver or any other enterprise application package. Using key point indicators specific to your plant, it allows users to make informed business decisions from plant floor and enterprise information. OLAP technology allows users to integrate cross-functional information, such as maintenance, production performance, capacity, and inventory data, into user-defined dashboards accessible across the enterprise.
Cayenta
cayenta.com
Circle 363
Software sizes vacuum vessels
Vacworks II is an interactive CD-ROM program for vacuum system design. It provides upgraded calculation capabilities, including vacuum system sizing for pressures as low as 1 torr, adding component vapor pressure data, condensate drain leg height calculations, and piping pressure drop evaluation. The program assists in the sizing and design of thermo-compressors and vacuum systems, including steam jet ejector, liquid ring pump, and hybrid systems. It can handle tubeside, shellside, or direct-contact condensing and allows the printing of data sheets, equipment drawings, and process flow diagrams.
Graham
Graham-mfg.com
Circle 364
Adaptive software controls in real time
CyboCon HS Model-Free Adaptive (MFA) is high-speed adaptive control software capable of handling applications that require control response in the 1%%MDASSML%%10-msec range, such as process, motion, and robotics control. Depending on the number of loops and the hardware used, it can offer typically a 10-msec control update rate with 16%%MDASSML%%32-MFA controllers. The software runs on PCs with Windows NT or 2000, at least a 700-MHz processor, and 256 MB of RAM. It includes a single-input/single-output (SISO) MFA controller, antidelay MFA controller, and nonlinear MFA controller for significant gain changes.
CyboSoft
cybosoft.com
Circle 365
CMMS/EAM offers choice
TabWare is now available for implementation at plant or enterprise locations as TabWare OnSite or as an application service provider (ASP) solution as TabWare OnLine. The products are the same; only the delivery method differs. They organize work processes into tabbed modules: equipment, predictive maintenance, purchasing, event tracking, resources, graphics, work orders, inventory, setup, scheduling, requisitions, security, preventive maintenance, supplier, and invoice matching. The ASP version features high-speed link and data security.
Fluor Corp.
tabware.com
Circle 366
Pressure vessel software updated
PVElite Version 4.10 is integrated vessel design and stress analysis software. Updates in version 4.10 include the ASME 2000 addenda and ASCE 98 wind code, as well as provisions to use the 1999 material database. Other enhancements include user bolt loads in the tubesheet programs, simultaneous calculations for corroded and noncorroded thick expansion joints, separate entry of m and y factors for partition gaskets, addition of graphical results processing in rigging analysis, transparency option in the 3D viewer, and ladder specifications. It also incorporates current pressure vessel codes and standards.
COADE, Inc
coade.com
Circle 367
Upgrade minimizes memory usage
LightWorks v5.6 is an upgrade to the LightWorks rendering technology for producing photorealistic 3D images and animations. The upgrade adds extensions to the software's Interactive Image Regeneration and anti-aliasing shader, and increased speed in complex models and multithreaded rendering. The enhancements can typically increase the rendering performance for complex CAD assemblies and models containing millions of polygons by 2%%MDASSML%%5 times. Control over reading and access of textures has been extended to allow dynamic texture caching to minimize memory usage. Management of low-level memory allocations has been extended to allow greater flexibility in controlling memory accesses.
LightWork Design, Ltd.
lightwork.com/products/ lightworks/5.6/LW5.6.htm
Circle 368
Program computes section properties
Sectionwizard software facilitates calculation of section properties for custom or assembled shapes. It enables engineers to calculate section properties such as area, moment of inertia, section modulus, center of gravity, shear center, and torsional constants. It creates custom shapes from built-in sections and plates; finds equivalent standard sections with properties comparable to a custom or built-up sec-tion; computes stresses at any point of a cross-section based on axial forces and moments about principal axes; and creates free-form sections, insert openings, and create chamfers and radii. It is also compatible with metric and imperial unit systems.
Research Engineers Intl.
reiworld.com
Circle 369
ERP incorporates SQL
Made2Manage 4.0 SQL Enterprise Edition software features the company's flagship enterprise resource planning (ERP) product, and is designed to help all levels of a business work together better. Version 4.0 SQL includes TOC-based scheduling, a synchronizer, multisite management, and multidimensional inventory. It offers a field service module, Visual Basic, an Explorer link, and SQL Server, which allows the software to run on a true client/server database engine.
Made2Manage Systems, Inc.
made2manage.com
Circle 370
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.