Software: Design, Modeling, Analysis

Finalists in the Software: Design, Modeling, Analysis category for the 2012 Product of the Year competition

Emma Renee Dutton, Content Specialist

04/16/2012


Electrical design software

Design Master Electrical 8.0Design Master Software has improved support for 3-D-BIM in Design Master Electrical 8.0, which can now export an IFC file for 3-D collision detection. This software runs inside AutoCAD and its 3-D model now includes conduits, cable trays, and vertical panel clearances, which are exported as 3-D solids in the IFC file. This software update also includes a material takeoff feature available to all users, equipment sizing based on MCA and MOCP, an improved voltage drop schedule, a command to update all schedules on the drawing, a toggle to hide devices in one-line diagram, a command to join broken circuits, and motor voltage options above 600 V.


Data center management software

StruxureWareSchneider Electric’s StruxureWare for data centers is a second-generation, vendor-neutral management software suite that enables an integrated view of the physical systems of the data center to provide data gathering, monitoring and automation, and planning and implementation functionalities. From a single point of access, it provides intelligent monitoring, automation, planning, and reporting on critical facility management systems. This software consists of seven applications that provide users with multiple options to create and share management dashboards, from detailed reports on single assets to broader perspectives for global operations. The dashboards offer multisite options to support comparisons and corporate energy governance activities.


Building efficiency system

PanoptixPanoptix is a combination of software and services designed by Johnson Controls to monitor and improve building performance for any size facility. The software includes an open technology platform for collecting and managing data from disparate building systems and other data sources, as well as a suite of cloud-hosted building efficiency applications that work with any building management system. The system includes four applications that detect abnormal energy consumption, track energy usage and carbon emissions, create energy baseline models, and provide comparative analysis. With Panoptix, the company provides building and energy services to help customers implement operational improvements and energy-savings measures on-site, online, and by phone.


<- Back to: Product Categories



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.