Safety light curtains, limit switches for industrial machine safety

AutomationDirect now offers machine safety devices for use in industrial applications. Two series of safety light curtains are designed for human protection and machine safety where risks cannot be eliminated by machine design and the process might require frequent and open access during operation.

12/20/2010


AutomationDirect offers industrial machine safety light curtains and limit switches.AutomationDirect offers machine safety devices for use in industrial applications. Two series of safety light curtains (active optoelectronic protective devices) are designed for human protection and product/machine safety where risks cannot be eliminated by machine design and the process might require frequent and open access during operation.

The YBB-14 series has a 14mm sensing resolution for finger-size protection and an operating distance of up to 3.5 meters; protective heights range from 142 mm to 1,045 mm. The YBB-30 light curtains series has a 30 mm sensing resolution for hand protection and an operating distance of up to 12 meters; protective heights range from 279 mm to 1,827 mm.

All safety light curtains have Type 4 and Cat 4 PL e safety ratings and are IP65 rated. Mounting brackets are included with each unit and additional mounting accessories and protective columns are available.

AutomationDirect has also added a line of machine guarding safety switches to detect unsafe conditions and isolate power. Normally-closed contacts are used for a positive break and redundant normally-closed contact and normally-open feedback outputs are available. The safety switches cannot be easily defeated and all units have CE, UL and CSA approvals. Four bases are available: 30 mm plastic, 50 mm zinc alloy, 40 mm aluminum and 60mm aluminum. Four types of interlocks  are available for common safety applications including tongue (key), shaft hinge, lever hinge interlocks and pull cord actuators with reset for emergency stop or without reset for simple stop.

See the full line of safety products and prices at www.automationdirect.com/safety.

Read the Control Engineering Machine Safety blog at www.controleng.com/blogs/machine-safety.html.

- Edited by Mark T. Hoske, CFE Media, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me