SEARCH Archives
Loading
Sponsored by:

Relay protects against ground-fault hazards with variable speed drives

Littelfuse EL731 AC/DC Sensitive Earth-Leakage Relay provides complete range of ground-fault protection in variable speed drives from 0 Hz to 15,000 Hz in one device. See video clip.

01/24/2013

Flash is required!

 

Littelfuse EL731 AC/DC Sensitive Earth-Leakage Relay provides a complete range of ground-fault protection in variable speed drives from 0 Hz to 15,000 Hz in one device. See video clip.

Littelfuse Inc., provider of electrical safety, power distribution, and power control products, offers the Littelfuse EL731 AC/DC Sensitive Earth-Leakage Relay, which can detect ground currents—even in resistance-grounded electrical systems—down to 0 Hz. This makes it ideal for protecting variable-frequency drives (VFDs) that may operate at low speeds, during which ac current approaches dc.

The EL731 relay provides a complete range of ground-fault protection in VFDs from 0 Hz to 15,000 Hz in one device, saving cost and panel space compared to other relays.

The relay uses a patented approach that enables the relay to detect the location of ground faults and makes it equally useful for ac, mixed ac/dc, and dc systems, including low-voltage 6-pulse VFDs commonly used on motors up to 250 hp. It can reliably protect a variety of applications, including conveyor belts, cranes, compressors, pumps, and mixers found in demanding environments, such as mining, oil sands operations, chemical plants, food processing, and other industrial facilities.

At its introduction, Tony Locker, PE, Littelfuse product manager, said, “This is the first relay to adequately address the common challenge of detecting ground faults in VFDs operating at low speed.” (See additional comments and explanation from Locker in the short video clip.)

The new relay is ideal for protecting VFDs operating in resistance-grounded electrical systems, which are growing in popularity because of their ability to reduce arc-flash hazards. The on-board ground-fault protection that comes with VFDs is generally not sensitive enough to detect a ground fault in resistance-grounded systems.

The EL731 can be installed in place of an existing ground fault relay without replacing the current transformer (CT). Two CTs are required for the entire frequency range, or one CT can be used for only low- or high-frequency detection. The relay has a temperature input, metering capabilities, password protected alarm, and trip settings. Ethernet communications port is optional.

Video clip, above, explains the hazards of VFD ground faults and solution: Because variable frequency drives typically cannot pick up a ground fault, there’s potential for employee shock hazard and equipment damage. There is a solution, according to Locker. VFDs or variable speed drives (VSDs) typically aren’t able to pick up low-level ground faults, which can lead to a safety hazard. Most end-users may be unaware of the risk, Locker said in the video. VFD ground-fault detection is around 20% full-load current, so if you have a 100 A drive or 100 A motor, that means that 20 A is the lowest level at which that drive will detect a ground fault. He said high-resistant ground systems are limited to 5 A. There have been documented cases where a loose connection terminal block on a motor loosened and created a fault to ground, without the drive or motor knowing it. In one case, such a fault burned a 2-in. hole in motor terminal cover, while the motor continued to operate, creating an electrocution and fire hazards, he warned. A ground fault relay could be added to the circuit to avoid such a hazard, and provide filtering, as well, he said.

Learn more about the EL731.

www.littelfuse.com/acdc 

www.littelfuse.com/ProtectionRelays 

- Text edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske(at)cfemedia.com. Video edits by Peter Welander, content manager, CFE Media.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.