Powerful transfer switch control

Russelectric RTS Series 30-cycle-rated and 3-cycle-rated automatic transfer switches have the company’s new RPTCS microprocessor automatic transfer control system for the emergency/backup power industry. Systems are programmed at the factory to include customer options.

04/06/2011


Russelectric RTS Series 30-cycle-rated and 3-cycle-rated automatic transfer switches have the company’s new RPTCS microprocessor automatic transfer control system for the emergency/backup power industry. Russelectric RTS Series 30-cycle-rated and 3-cycle-rated automatic transfer switches have the company’s new RPTCS microprocessor automatic transfer control system for the emergency/backup power industry. Each system is programmed at the factory to include customer-specified options. Setup, alarm acknowledgement, and review of actual data are easily accomplished using the controller’s soft keys and color display.  The intuitive, interactive menu guides the user through controller setup and the entering of configuration data, including communications and timing set points, adjustable control parameters (interlocks, alarms, and security), and event logging.

Real-time metering of voltage (phase-to-phase and phase-to-neutral) and frequency of both normal and emergency power sources is standard.  Available options include metering of phase and neutral current; percent of unbalanced current; percent of unbalanced voltage; accumulated energy (KWH, KVAH, and KVARH); and per-phase and 3-phase totals for real power (KW), apparent power (KVA), reactive power (KVAR), and power factor.  The RPTCS can also monitor power quality with available waveform capture and historical trending.  All metering can be accessed through the menu.

The controller senses the voltages of both power sources and, by means of easy-to-see LEDs, indicates switch position and source availability.  Through the menu, users can also review operational data such as active time delays, transfer inhibits, metered values, fault and alarm reports, event records, and configuration settings.  The controller also automatically displays the status of monitored conditions (faults, alarms, inhibits, etc.) and conveys other messages in color-coded banners at the top of the screen.

The RPTCS controller supports two communication interfaces: standard Modbus RTU or available Modbus TCP/IP via 10/100 Base-T Ethernet.  An external communication port on the controller’s faceplate allows fast, easy connection to a laptop.

www.russelectric.com

See the Machine Control Channel at www.controleng.com/machinecontrol

- Edited by Mark T. Hoske, CFE Media, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me