Power monitoring and metering module

Eaton's new PM3 module is designed to monitor the power of branch and main circuit applications to help system reliability and reduce utility costs.

09/29/2011


Eaton is expanding its circuit protection products with the PM3 power monitoring and metering module, which monitors the power of branch and main circuit applications. The PM3 is a device that measures current and voltage, calculates power and energy usage, and provides breaker status. It is designed for Eaton Series G L-Frame and Series C K-Frame molded-case circuit breakers. Engineered for original equipment manufacturers (OEMs), the PM3 module is applied where monitoring is important. 

“The PM3 module is designed to improve electrical system reliability and efficiency, by helping to reduce utility costs and increase equipment performance,” said Shawn Diamond, product manager at Eaton. “It enables real-time monitoring, metering and communication of phase current and voltage, with real and reactive calculated power and energy – making it easier for customers to detect potential power concerns.”

An Underwriters Laboratories (UL) listed, add-on communications device, the PM3 module can be mounted to the load side of three-pole Series G LG and Series C KD breaker frames and monitors electrical system parameters, Eaton said. Regardless of whether the trip unit is thermal-magnetic or electronic, the PM3 can be adapted to applications where monitoring is critical. It can also be installed in reverse-feed applications with reverse-fed breakers. Measurement accuracy is within two percent of the reading.

The PM3 power monitoring and metering module communicates through INCOMTM protocol, and is compatible with Eaton Power Xpert Gateway (PXG) for web page and Ethernet capability. Versatile, it communicates to the web or Modbus TCP/IP through any of the Eaton PXG gateways.

Available in two versions, the 480 volt (V) PM3 module operates in 208 V to 48 0V applications, and includes an integral power supply. The 600 V model operates 208 V to 600 V applications and requires 24 V direct current auxiliary power, the company said.

www.eaton.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me