Plant Relocation to N.Y. and Build-out of New Machine Shop

Existing building retrofit; Plant Relocation to N.Y. and Build-out of New Machine Shop; Optimation Technology Inc.

08/15/2013


The new building façade is shown. Courtesy: Optimation TechnologyEngineering firm: Optimation Technology Inc.
2013 MEP Giants rank:
20
Project:
Plant Relocation to N.Y. and Build-out of New Machine Shop
Address:
Rochester, N.Y., United States
Building type:
Manufacturing
Project type:
Existing building retrofit
Engineering services:
Code Compliance, Electrical/Power, HVAC, Lighting
Project timeline:
February 2012 to November 2012
Engineering services budget:
$1.3 million
MEP budget:
$3.2 million

Challenges

After purchasing the assets of custom machine builder Kingsbury Corp. in Keene, N.H., Optimation laid plans to relocate all purchased equipment to its own facility at 1600 Lexington Avenue in Rochester. This was a fast-track project; machinery and equipment needed to be dismantled, crated and shipped, installed, and running in its new location quickly to begin work on spare parts orders already coming in from clients.

Solutions

Optimation designed the new 180,000-sq-ft machine shop including a new Kingsbury main office complex in Rochester. Beginning in March of 2012, Optimation skilled trades began dismantling, rigging, and crating 105 truckloads of Kingsbury equipment to be installed in the empty shop space. Optimation's engineers, designers, skilled tradesmen, and IT specialists all worked together to complete this massive project, a total investment of $4 million. Optimation skilled tradesmen installed the HVAC, electrical power, compressed air, and water lines to power each machine. Optimation's project managers subcontracted non-core competencies such as trucking and shipping, concrete foundations, drywall, painting, tiling, and carpeting. Project managers also worked closely with the Town of Greece to meet building requirements, codes, and regulations. Within 9 months, the new shop was up and running and fulfilling orders. This tight schedule was met only because of Optimation's ability to self-perform with its full set of engineering, skilled trades, and project management services.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me