Pipe hangers and supports standards updated

The Manufactures Standardization Society has published a comprehensive standard practice for pipe hangers and supports.

Source: Manufactures Standardization Society

11/05/2009


 

The Manufactures Standardization Society (MSS) has published a newly revised and enhanced Standard Practice, SP-58-2009, Pipe Hangers and Supports - Materials, Design, Manufacture, Selection, Application, and Installation.

This comprehensive Standard Practice combines all of the content of five Pipe Hanger and Support standards into a single document. MSS SP-58-2009 will serve as a complete guide for pipe hanger and support design, manufacture, selection, and installation, enabling the user to specify a minimum level of acceptance for pipe hanger design and performance, in addition to defining the types of hangers and supports.

MSS SP-58-2009 includes all of the information from ANSI/MSS SP-69, Selection and Application; MSS SP-77, Guidelines for Pipe Support Contractual Relations; MSS SP-89, Fabrication and Installation Practices; and MSS SP-90, Guidelines on Terminology for Pipe Hangers and Supports.

The scope of this revised Standard Practice:

• Establishes the material, design, fabrication, and inspection criteria to be used in the manufacture of standard types of pipe hanger components
• Establishes the allowable stress values for materials used in standard types of pipe support components and unique hanger design assemblies
• Establishes minimum design load ratings for rigid pipe hanger assemblies
• Presents the recommended practice for the selection and application of pipe hangers and supports for all service temperatures
• Establishes recommended procedures for detailing, fabrication, and installation of pipe hangers and supports
• Serves as a pipe hanger and support specification for selection and application
• Serves as a guide to proven industry practice during engineering design and writing of job specifications covering the hanging, supporting and controlling the movement of piping systems
• Provides the erector with information on types of hanger and support components to be used for specific application and installations, where such information is not otherwise provided
• Serves as a companion document to MSS SP-127 which provides recommendations for the design, selection, and application of bracing for piping systems subject to seismic- wind - dynamic loading.

The content of this Standard Practice provides an effective, clear, and non-exclusive specification that benefits the industry as a whole and provides a basis for common practice by manufacturers, users, and the general public.

Order information is available online.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.