PCI Carrier Board

Wixom, Mich.— Acromag's new APC8620 PCI board interfaces up to five IndustryPack-type ANSI/VITA-4 modules to a PC. By installing analog, digital, and serial I/O modules on the APC8620 carrier card in any combination, users can efficiently develop custom I/O boards with high channel density. Users can also choose from more than 40 Acromag IP modules or hundreds available from third parties.

03/01/1998


Wixom, Mich.— Acromag's new APC8620 PCI board interfaces up to five IndustryPack-type ANSI/VITA-4 modules to a PC. By installing analog, digital, and serial I/O modules on the APC8620 carrier card in any combination, users can efficiently develop custom I/O boards with high channel density. Users can also choose from more than 40 Acromag IP modules or hundreds available from third parties. Object linking and embedding (OLE) software for Microsoft Windows 95/NT simplifies integrating Acromag's IP modules into data acquisition and control applications with easy object-oriented programming. The OLE controls are object-based software components that function as drivers to give easy access to IP module I/O data for use in OLE-compatible programs, such as Visual Basic, Visual C++, Borland Delphi, and many human-machine interface software products. These OLE controls handle many common functions, such as register reads, writes, and interrupts to eliminate many programming chores.

Acromag





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me